Carrier 58MTA Installation, Start-Up, And Operating Instructions Manual page 2

Direct vent condensing gas furnace

Advertisement

Two-Stage
Heating
With Two-Stage
Thermostat
(Non-Adaptive
Heating
Model
.........................................
36
Cooling
Mode ....................................................................
36
Thermidistat
Mode ............................................................
39
Continuous
Blower
Mode
.................................................
39
Heat Pump .........................................................................
40
Start-Up
Procedures
................................................................
40
Purge G_L_ Lines ................................................................
40
Component
Self-Test
.........................................................
40
Prime Condensate
Trap
With
Water .................................
40
Operate
Furnace
.................................................................
41
Furnace
Restart ..................................................................
4 I
Adjustments
.............................................................................
4 I
Set Gas Input Rate ............................................................
41
Set Temperature
Rise ........................................................
45
Adjust
Blower
Off Delay
(Heat
Mode) ............................
46
Set Thermostat
Heat Anticipator
......................................
46
Check
Safety
Controls
............................................................
47
Checklist
..................................................................................
47
RATING
CERTIFIED
REGISTERED QUALITY SYSTEM
SAFETY CONSIDERATIONS
Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature
rise, unit leveling,
and unit sizing. Improper
installation or misapplication of furnace can require excessive
servicing or cause premature component failure.
Improper
installation,
adjustment,
alteration,
service,
mainte-
nance, or use can cause
carbon
monoxide
poisoning,
explo-
sion. fire.
electrical
shock,
or other
conditions
which
may
cause personal
injury or property
damage.
Consult
a qualified
installer,
service
agency,
local
gas supplier,
or your distribu
tot or branch
for information
or :Lssistance.
The
qualified
installer
or agency
must
use
only
factory-authorized
and
listed kits or accessories
when modifying
this product.
Failure
to follow
this warning
could
result
in electrical
shock,
fire.
personal
injury,
or death.
Installing
and servicing
heating
equipment
can be hazardous
due to
gas
and
electrical
components.
Only
trained
and
qualified
personnel
should
install,
repair,
or service
heating
equipment.
Untrained
personnel
can
perform
basic
maintenance
functions
such as cleaning
and replacing
air filters. All other operations
must
be performed
by trained
service
personnel.
When
working
on
2
heating
equipment,
observe
precautions
in literature,
on tags, and
on
labels
atlached
to or shipped
with
unit
and
other
safety
precautions
that may apply.
These
instructions
cover the minimum
requirements
and conform
to existing
national
standards
and safety codes.
In some instances,
these
instructions
exceed
certain
local
codes
and
ordinances,
especially
those that may not have kept up with changing
residen
tial
constt_ction
practices.
We require
these
instructions
xs a
minimum
for a safe installation.
We,u- safety
glasses
and work glo_es.
--9
Have a fire extinguisher available during start-up and adjustment
procedures and service calls.
Recognize safety information, This is the safety-alert symbol z_,
When you see this symbol on the unit and in instructions
or
manuals, be alert to the potential for personal injury.
Understand
these signal words: DANGER, WARNING,
CAU-
TION, and NOTE. These words are used with the safety-alert
symbol. DANGER identifies the moat serious hazards which will
result in severe personal injuD" or death. WARNING
sigltifies
hazards which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or product and property" damage. NOTE is used to
highlight suggestions
which will result in enhanced installation,
reliability, or operation.
AIRFLOW
-CY
AIRFLOW
AIRFLOW
A93041
Fig. 1--Multipoise
Orientations
INTRODUCTION
The model
58MTA,
2-Stage,
4-way
multipoise,
Gas-Fired,
Cat
egory
IV, direct
vent condensing
furnace
is available
in model
sizes
ranging
in high-stage
gas input rates of 60,000
to 120.000
Btuh.
This
furnace
is C.S.A.
design-certified
for natural
and
propane
gases
(see furnace
rating
plate)
and
for installation
in
alcoves,
attics,
basements,
closets,
utility rooms,
crawlspaces,
and
garages.
This furnace
is factory-shipped
for use with natural
gas. A
C.S.A.
listed gas conversion
kit is required
to convert
furnace
for
use with propane
gas.
This
furnace
shall
not be installed
directly
on ca_eting,
tile, or
any other
combustible
material
other
than
wood
flooring.
FOC