Fixed High Limit and Electric Heating Element Temperature Adjustment

Fixed High Limit
The high limit safety feature is factory set at
180°F5°F (82°C3°C)
DHW Temperature Adjustment
The factory preset DHW temperature is 120°F 5°F
(49°C3°C) at "HOT" indicator setting.
The DHW temperature is field adjustable between
110°F to 160°F (43°C to 71°C).
The factory temperature differential (non-adjustable) is
between 7°F to 17°F (4°C to 9°C).
CAUTION
For your safety DO NOT attempt to repair thermostat,
heating element or electrical wiring (if applicable).
Always refer such repairs to a qualified service technician.
Fixed High Limit
(Manual Reset)
DHW
Temperature
Adjustment
Heating element temperature settings
To adjust the temperature settings:
1. Turn "off" the electrical power at the junction box
of the water heater.
WARNING
Failure to turn "OFF" electrical power to the
solar water heater will result in the possibility
of property damage, serious injury or loss of
life.
2. Carefully take off the access panel (see page 25).
3. Turn the water temperature dial clockwise to increase
the temperature, or counterclockwise to decrease the
temperature.
Thermostat Setting
°
HOT
A
B
C
VERY HOT
4. Carefully replace the access panel.
5. Turn "on" the power supply.
IMPORTANT
Each thermostat is factory preset at "HOT" or
1205°F (493°C). This setting will reduce the risk
of scald injury. This temperature setting has proven
by experience to be the most satisfactory from the
standpoint of operation costs, household needs and the
ability to store solar generated heat.
Solar water heaters installed in Florida require the
thermostat to be set at 125°F (52°C).
Approx. Water
Temperature
120°F (49.0°C)
125°F (51.5°C)
130°F (54.5°C)
135°F (57.0°C)
140°F (60.0°C)
150°F (65.5°C)
160°F (71.0°C)
170°F (76.5°C)
Installation
Approx. DHW Temperature
110°F5°F (43.5°C3°C)
120°F5°F (49.0°C3°C)
130°F5°F (54.5°C3°C)
140°F5°F (60.0°C3°C)
150°F5°F (65.5°C3°C)
160°F5°F (71.0°C3°C)
Time to produce 2nd and 3rd
Degree burns on adult skin
more than 5 minutes
1.5 to 2 minutes
about 30 seconds
about 10 seconds
less than 5 seconds
about 1.5 seconds
about 0.5 seconds
nearly instantaneous