Advertisement

Error message on the
display
Please make sure the
exhaust hose is not
blogged, bent or fro-
zen. Press OK for re-
start.
Fuel cartridge empty.
Please replace the fuel
cartridge, and press
OK.
Please refill service
fluid Press OK for re-
start.
Interruption:
Cooling insufficient.
Please check installa-
tion and air supply!
Page 70
Error
Solution
code
11
Please check the installation of
18
the exhaust hose and position it
so that no condensation can
gather. Do not bend the exhaust
hose. If necessary, clean the ex-
haust hose and protect the open-
ing from becoming clogged.
Shorten the exhaust hose if con-
densation is gathering in it.
20
See chapter 5.4 "Fuel car-
22
tridges" on page 53.
30
Make sure that the off-heat can
escape without obstruction and
that the ambient temperature is
below 50°C/122°F. If the fuel cell
is installed within a sealed con-
tainer, please ensure that the
opening for supply air has a
cross-section of at least
10 cm/3.94 in. Then refill the
fuel cell with service fluid (see
chapter 7.3 "Adding service flui-
d" on page 73).
32
The cooling air is insufficient or
the ambient air is too warm.
Please check whether the room
in which the fuel cell is installed
has sufficient ventilation, or
whether the openings for the air
supply in the EFOY Pro fuel cell
are blocked.