EFOY Pro 800 Operation And Installation Manual page 51

Hide thumbs Also See for Pro 800:
Table of Contents

Advertisement

Permitted value ranges for LiFePO4 batteries (12 V) – FW 17.07
Switch-on voltage
Switch-off voltage
Switch-off voltage
(Hybrid)
Switch-off current
EFOY Pro 800
EFOY Pro 2400
Switch-on delay
Absorption time
Max. charge time
Altitude up to
Permitted value ranges for LiFePO4 batteries (24 V) – FW 17.08
Switch-on voltage
Switch-off voltage
Switch-off voltage
(Hybrid)
Switch-off current
EFOY Pro 800
EFOY Pro 2400
Switch-on delay
Absorption time
Max. charge time
Altitude up to
Page 50
Factory
Min.
defaults
13,3 V
12,0 V
14,5 V
13,8 V
14,6 V
13,5 V
2,0 A
1,0 A
4,0 A
4,0 A
60 s
2 s
180 min
0 min
24 h
2 h
1500 m
0 m
Factory
Min.
defaults
26,6 V
24,0 V
29,0 V
27,6 V
29,2 V
27,6 V
1.0 A
1.0 A
2.0 A
2.0 A
60 s
2 s
180 min
0 min
48 h
2 h
1500 m
0 m
Operation
Max.
User-defined
value:
13,4 V
14,6 V
15,5 V
10,0 A
10,0 A
300 s
300 min
120 h
2000 m
Max.
User-defined
value:
26,8 V
29,2 V
31,0 V
5.0 A
5.0 A
300 s
300 min
120 h
2000 m