Supply air
at least
10 cm/
3.95 in
ø
ø
Exhaust air
The space in which the device is to be
installed (including safety distance)
must be at least
L x W x H: 51 x 35 x 30 cm/
20.1 x 13.8 x 11.8 in.
If the fuel cell is installed within a
sealed container, provide an opening
for supply air with a cross-section of at
least ø 10 cm/ ø 3.95 in – at structured
openings (fine grid, narrow gap), ac-
cordingly more.
Use the off-heat duct to conduct the
off-heat out of the installation space
(see chapter 4.3 "Connecting the off-
heat duct" on page 23).
The air openings of the installation
space need to be protected against the
penetration of water and foreign parti-
cles (e.g. using louvered metal sheets
and fly screens).
Ensure that there is sufficient ventila-
tion in the installation space to prevent
heat build-up. This can be done with
additional openings or an additional
temperature-controlled fan.
The electrical connections, the fill
opening for service fluid, and the fuel
cartridge must be easily accessible.
Installation