EFOY Pro 800 Operation And Installation Manual page 50

Hide thumbs Also See for Pro 800:
Table of Contents

Advertisement

Operation
Permitted value ranges for Lead-acid, -gel & AGM batteries (12 V)
Switch-on voltage
Switch-off voltage
Switch-off voltage
(Hybrid)
Switch-off current
EFOY Pro 800
EFOY Pro 2400
Switch-on delay
Absorption time
Max. charge time
Altitude up to
Permitted value ranges for Lead-acid, -gel & AGM batteries (24 V)
Switch-on voltage
Switch-off voltage
Switch-off voltage
(Hybrid)
Switch-off current
EFOY Pro 800
EFOY Pro 2400
Switch-on delay
Absorption time
Max. charge time
Altitude up to
Factory
Min.
defaults
12,3 V
11,0 V
14,2 V
13,5 V
14,7 V
13,5 V
2,0 A
1,0 A
4,0 A
4,0 A
60 s
2 s
180 min
0 min
24 h
2 h
1500 m
0 m
Factory
Min.
defaults
24.6 V
22.0 V
28.4 V
27.0 V
29,4 V
27,0 V
1.0 A
1.0 A
2.0 A
2.0 A
60 s
2 s
180 min
0 min
24 h
2 h
1500 m
0 m
Max.
User-defined
value:
13,0 V
14,7 V
15,5 V
10,0 A
10,0 A
300 s
300 min
120 h
2000 m
Max.
User-defined
value:
26.0 V
29.4 V
31,0 V
5.0 A
5.0 A
300 s
300 min
120 h
2000 m