TECHNICAL SPECIFICATIONS - POWER WAVE
POWER SOURCE-INPUT VOLTAGE AND CURRENT
Model
Duty Cycle
40% rating
K2675-1
100% rating
Process
Duty Cycle
GMAW
40%
GMAW-Pulse
FCAW
100%
40%
SMAW
100%
40%
GTAW-DC
100%
INPUT
VOLTAGE /
PHASE/
FREQUENCY
208/1/50/60
208/3/50/60
230/1/50/60
230/3/50/60
400/1/50/60
400/3/50/60
460/1/50/60
460/3/50/60
575/1/50/60
575/3/50/60
1 Wire and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
2 Also called "inverse time" or "thermal/magnetic" circuit breakers; circuit breakers that have a delay in tripping action that decreases as the
magnitude of current increases.
3 Type SO cord or similar in 30°C ambient.

INSTALLATION

Input Voltage ± 10%
208/230/400*/460/575
1/3 phase 50/60 Hz
(* includes 380V to 415V)
RATED OUTPUT
Volts at Rated Amperes
29
26.5
31.2
29
22
20
RECOMMENDED INPUT WIRE AND FUSE SIZES
INPUT AMPERE
RATING ON
NAMEPLATE
53
30
48
28
29
16
25
14
20
11
POWER WAVE
®
C300
Input Amperes
Idle Power
(1 Phase in paren-
thesis)
30/28/16/14/11
(53/48/29/25/20)
300 Watts Max.
23/21/12/11/9
(fan on)
(41/37/22/19/16)
CORD SIZES 3
2
AWG SIZES (mm
)
6 (16)
8 (10)
6 (16)
8 (10)
10 (6)
12 (4)
12 (4)
14 (2.5)
12 (4)
14 (2.5)
C300
®
A-1
Power Factor @
Rated Output
.95
Amperes
300
250
280
225
300
250
1
TIME DELAY FUSE
OR BREAKER
2
SIZE
(AMPS)
70
40
70
40
40
25
35
20
30
15