8.3.2
Description of maintenance
menu messages
MAINTENANCE
IThis function allows to show and reset the errors
that may be present. It is also possible to upkeep
the vending machine.
The error can be reset through the maintenance
menu or using the Automatic Error Reset mode.
Important
The latter, designed to be used by unskilled
technical personnel, can be activated without
entering the programming/maintenance menu
and tries to remove automatically any (non-
critical) error conditions that may occur in the
V.M.
Operational defects
Self-reset
No cups (cod. 08)
Drain tank full (cod. 09)
No brew group (cod. 20)
Recommended solutions
In maintenance mode it is possible to:
- move the gear motor of the brew group by
pressing beverage key 2;
- have the mixer rinsed by pressing beverage
key 3;
- display for 5 seconds total and partial
counters by pressing the beverage key 4.
- move the cup release / cup bracket gear
motor by pressing beverage key 6;
- reset errors by pressing beverage key 8
42
This mode does not eliminate all error conditions,
but only those caused by operational defects.
Errors are divided into two groups (defect and
failures) according to their criticality and therefore
according to the easiness of removing the
causes that determined them.
Defects include error conditions automatically
recovered when their cause ceases to exist, as
well as those conditions requiring an operator’s
intervention that, consequently, can be removed
only upon the operator’s request.
Failures, on the contrary, always require a
technical intervention of skilled personnel.
The following table shows the error conditions
divided into their two categories
automatic reset
No water (cod. 01)
No coffee (cod. 02)
Brew group blocked (cod. 03/04)
Cup s blocked (cod. 10)
Beverage/s blocked (cod. - -)
- Error / Message nn
It describes the current error - check the cause
in section 12 Error messages. If there are no
errors present, this message is not displayed.
After checking the cause of the error, press the
ENTER key to reset the vending machine - for
the complete list of errors see section 12.
Failures
manual reset
Flowmeter (cod. 05)
Arm blocked (cod. 06/07)
Boiler 1 temp. sensor (cod. 14)
Eeprom memory (cod. 16)
Cup basket blocked (cod. 17)
No timekeeper (cod. 25)
Position of decimal point (cod. 31)