Balance Refrigerant Of The 2-Way, 3-Way Valves - Midea MSG-24CR Service Manual

Room airconfitioner split wall-mounted type
Hide thumbs Also See for MSG-24CR:
Table of Contents

Advertisement

8.7

Balance refrigerant of the 2-way, 3-way valves

Procedure:
1. Confirm that both the 2-way and 3-way valves are set to the open position.
2. Connect the charge set to the 3-way valve's service port.
§ Leave the valve on the charge set closed.
§ Connect the charge hose with the push pin to the service port.
3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge
indicates 0.05 to 0.1 Mpa.
§ If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is
higher than 0.1Mpa, discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. If this is the
case, it will not be necessary to apply a evacuation.
§ Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil sill be
discharged.
- 28 -
Service manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msg-24hrMsg-30hrMsg-30crMsg-36crMsg-36hr