MedeaWiz® Sprite
Team Kingsley LLC
PLC Output Interfacing
The Sprite can be controlled from a Programmable Logic Controller using "dry contacts" like a
push button, or voltage output.
The sinking output is the preferred method if dry contacts are not available.
The Sprite has an internal 10K pullup so the Sourcing output requires a low resistance from
Output to Common to pull the Sprite's internal voltage down to a "LOW" The 1K* shown is an
example and can vary depending on the +V voltage. Consider the Watt rating of the resistor.
20 |
P a g e