Chapter 6: Mini-Controller Configuration
5250/Telnet
The format of the preloaded data is as follows:
The mode character used with the command allows for different operating modes to
suit various application operations. The automatic locate and fill operation applies
only to data received from a bar code reader. Descriptions of the modes and AIAG
prefix are listed in the table below. These modes are set at the host.
Mode
0
1
2
3
+4
+8
+16
AIAG Prefix
(data)
180
Teklogix 9150 Wireless Gateway User Manual
<mode> <AIAG prefix(data)>
Display prefix, send prefix to host.
Do not display prefix, send prefix to host.
Display prefix, do not send prefix to host.
Do not display prefix, do not send prefix to host.
Add 4 to above values to cause transmit to host when all AIAG fields with 4
set are filled. Function 0 is "pressed" if there are any fields
with this bit set, and all fields with this bit set have been filled by
operator input.
Add 8 to above values to allow overwrite of previously entered data.
Add 16 to above values to indicate cursor position priority for search and fill.
The text to be matched in the AIAG field.
Table 6.3 Mode Functions And AIAG Prefix Description
Function