Resetting the Oasis System
In the event of a fault in the Oasis system, the system will need to be reset.
To reset the Oasis system, press the exterior reset button on the face of the Oasis, or turn the burner switch off, then
back on inside the coach. The reset will clear faults such as Low Voltage, Flame Out, or a Low Fluid Level switch fault,
which typically clears on its own when the fluid level becomes sufficient. The Oasis will try to start twice when there is a
Flame Out fault. When it fails to start the second time, it will then display a fault on the face of the Oasis and on the
System Diagnostics screen within the SilverLeaf system (if equipped).
The exterior reset or the cycling of the ON/OFF button inside the coach will not reset the system if there is a
component fault, like a pump or other internal issues.
Any faults not resettable by cycling the switch or by the Oasis reset button should be diagnosed and repaired
by a qualified technician.
1
Material sourced from http://itrheat.com/products/oasis-heating-system/system-resources/frequently-asked-questions/
Thermostats
These brief operation instructions are for quick reference only. Any quick start instructions provided should
not take the place of the complete Operation Manual provided by this item's manufacturer.

Operating Controls

Set Clock Button
Pressing the CLOCK button will cause the HOURS setting to flash, allowing you to adjust the HOUR value using the up
and down arrows. Pressing the clock button a second time will cause the MINUTES setting to flash, allowing you to
adjust the MINUTES value using the up and down arrows. Pressing the clock button a third time will set the time, and
promptly exits out of the clock-setting mode.
Temp Format Button
Pressing the *F/*C button will allow you to choose between the Fahrenheit or Celsius settings.
Mode Selection Button
Pressing the MODE button allows you to choose between various options, depending on the system installed in your
coach. Choices may include the following:
• OFF = off
• COOL = setting for air conditioning
• AUTO = allows the thermostat to determine to use one of the heating options or cooling option to maintain a set
temperature
• HP = heat pump setting to use A/C to heat instead of cool