Dell XPS 600 Service Manual page 8

Hide thumbs Also See for XPS 600:
Table of Contents

Advertisement

Voltage (see the safety instructions
located in the Product Information
Guide for important voltage setting
information)
Backup battery
Physical
Height
Width
Depth
Weight
Environmental
Temperature:
Operating
Storage
Relative humidity
Maximum vibration:
Operating
Storage
Maximum shock:
Operating
Storage
Altitude:
Operating
Storage
Back to Contents Page
fixed-voltage power supply — 110 V at
50/60 Hz
manual selection and auto-sensing power
supplies — 90 to 135 V at 50/60 Hz; 180
to 265 V at 50/60 Hz; 100 V at 50/60 Hz
for Japanese computers
3-V CR2032 lithium coin cell
49.1 cm (19.3 inches)
22.2 cm (8.7 inches)
48.8 cm (19.2 inches)
19 kg (42 lb)
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
20% to 80% (noncondensing)
0.25 G at 3 to 200 Hz at 0.5 octave/min
0.5 G at 3 to 200 Hz at 1 octave/min
bottom half-sine pulse with a change in
velocity of 20 inches/sec (50.8 cm/sec)
27-G faired square wave with a velocity
change of 200 inches/sec (508 cm/sec)
–15.2 to 3048 m (–50 to 10,000 ft)
–15.2 to 10,668 m (–50 to 35,000 ft)