description
notes
5 3 DIAGNOSTICS
5 3 0 Room Temperature Zone 2
only active when the BUS device is connected
5 3 1 Flow Temperatuyre Zone 2
Only active with Heating Zones Modules Management
5 3 2 Return Temperature Zone 2
Only active with Heating Zones Modules Management
5 3 3 Set Heating Temperature Zone 2
only active when the BUS device is connected
5 3 4 Heat Request Zone 2
5 3 5 Pump Status Zone 2
Only active with Heating Zones Modules Management
DIAGNOSTICS
5 4
Only active with Heating Zones Modules Management
5 4 0 Operation Mode - Test
5 4 1 Valve control
5 4 2 Pump control
MULTIZONE
5 5
Only active with Heating Zones Modules Management
5 5 0
Heating collector
temperature
5 5 1
Heating collector fl ow outlet
temperature off set
7 TEST & UTILITIES
7 0 0 Test Mode
Enabled also by pressing for 10 seconds the Reset button.
This function is deactivated automatically after 10 minutes,
or when the RESET button is pressed.
7 0 1 Air purge Function
8 SERVICE PARAMETERS
8 1 SERVICE CODE
press the programming "+" button to select 234 and press the
M
button
ENU
8 2 BOILER
8 2 0 Set temperature Central
Heating(°C)
8 2 1 Fun Status
8 2 2 NOT ACTIVE
8 2 3 Pump speed
8 2 4 Diverter valve position
8 2 5 D.H.W. Flow Rate (l/min)
8 2 6 Air Pressure Switch Status
settings - adjustment - problem identifi cation menus
value
0 = OFF - 1 = ON
0 = OFF - 1 = ON
0 = OFF
1 = ON
3 = Manual
0 = OFF
1 = open
2 = closed
0 = OFF
1 = ON
from 0 to 120 (°C)
from 0 to 40 (°C)
t -- = Max Heating
0
power
--
t
= Max DHW power
t
= Minimum power
--
Press Menu/Ok button to
active
222
from 0 to 165 mA
0 = OFF - 1 = ON
0 = OFF
1 = Low speed
2 = High speed
0 = D.H.W.
1 = Central Heating
0 = Open
1 = Closed
description
notes
8 3 BOILER TEMPERTURE
8 3 0 Set temperature Central Heating(°C)
8 3 1 Flow Heating temperature (°C)
8 3 2 Return Heating temperature (°C)
8 3 3 Domestic Hot Water Temperature (°)
8 4 SOLAR & STORAGE
8 4 0 Storage Temperature - NOT ACTIVE
8 4 1 Solar collector Temperature
8 4 2 D.H.W. Inlet Temperature
8 4 3 NTC Storage Low
8 4 4 Storage Set-point stratifi cation
8 4 5 Solar pump run time (hour/10)
8 4 6 Collector overheat Temp Time (hour/10)
8 5 SERVICE
8 5 0
NOT ACTIVE
8 5 1
NOT ACTIVE
8 5 2
NOT ACTIVE
8 5 3 NOT ACTIVE
8 5 4 P.C.B Hardware version
8 5 5 P.C.B Software version
8 5 6
P.C.B BUS Software version
8 6 STATISTICS
8 6 0
Hours Burner On (Central Heating) (XXh)
8 6 1
Hours Burner On (Domestic Hot Water) (XXh)
8 6 2
Number of Flame Faults
8 6 3
Numbeer of ignition Cycles
8 6 4
NOT ACTIVE
8 6 5
Heat request Duration
8 7 NOT ACTIVE
8 8 ERROR HISTORY
8 8 0 Last 10 errors
This parameter makes it possible to see the last 10 errors
shown by the boiler as well as the relevant day, month and
year. Access the parameter to bring up the sequence of errors
from number E00 to number E99.
The following data is shown in a sequence for each single
error:
E 00 - error number
1 08 - error code
A 15 - day when the error occurred E00
B 09 - month when the error occurred E00
C 06 - year when the error occurred E00
(only with remote control Clima Manager connected)
8 8 1 Reset Error List
value
from E0 to E9
Reset? Ok=Yes
Esc=No
51