Check the amperage of the receptacles used referring to TABLE 1, and be
sure not to take a current exceeding the specified amperage.
Be sure that the total wattage of all appliances dose not exceed the rated
output of the generator.
Style
WARNING
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.
Be sure to ground the generator if
the connected electrical device Is
grounded.
NOTE :
When the
AC circuit breaker turns off during operation, the generator is over
loaded or the appliance is defective. Stop the generator immediately, check the
appliance and / or generator for overloading or detect and have repaired as
necessary by Makita factory or authorized service center.
Ampere
Receptacle
NEMA
up to 20A
L5-20R
NEMA
up to 30A
L5-30R
NEMA
up to 30A
L14-30R
up to 50A
TABLE 1
− 13−
AC plug
Description
NEMA
(REC1)
L5-20P
NEMA
Locking Receptacle
L5-30P
(REC2)
NEMA
Locking Receptacle
L14-30P
(REC3)
Locking Receptacle
(REC4)