Technical Specifications
COOLARC 46
COOLARC 46
The cooling power of flow 1liter per minute at
COOLARC 46
COOLARC 46
COOLARC 46
COOLARC 46
COOLARC 46
Protection Rating
IP23
English
NAME
Input Voltage U
230 V ± 10%
400 V ± 10%
Frequency
50/60 Hz
PARAMETERS RATING
temperature of 25°C
1 kW
PARAMETERS O FTHE COOLER'S RESERVOIR
Maximum reservoir capacity
6 l
Recommended
coolant
Do not use!!
Pre-packaged welding industry coolants. These coolants may contain
oil-based substances, which attack the plastic components of the
cooler. Once added to the cooler, these substances are impossible to
purge from the water lines and heat exchanger.
Automotive anti-freeze. These coolants will damage the pump and
block of the heat exchanger, affecting cooling performance.
PHYSICAL DIMENSIONS
Weight
22,7 kg
Operating Humidity
(t=20°C)
≤ 90 %
INPUT
1
Minimum required reservoir capacity
COOLANT
Height
255 mm
Operating Temperature
from -10 ºC to +40 ºC
8
INDEX
K14105-1
Input Amperes I
1max
0,65 A
EMC Group / Class
II / A
Maximum pressure rate
0,4 MPa
4 l
Acorox
Width
300 mm
700 mm
Storage Temperature
from -25 ºC to +55 ºC
Length
English