3.1.2 False chimney brest RELAXED L with frame
Make a framework of metal studs around building guides A and B (fig. 3-1); keep in
mind the thickness of the Promatec you use!
Place metal studs at every corner of the false chimney brest; keep in mind the
thickness of the Promatec you use!
Build with Promatec around the appliance against the building guides A and B (fig.3-1);
keep in mind that the appliance has to stick out of the walll and therefore nothing
must be build before the building guides!
Build the rest of the false chimney brest

3.2 Flue requirements

The appliance is of the type C11/C31. The appliance will need to be supplied with
the approved flue pipes and terminal, it is not possible to supply your own
a horizontal extension with elbows is allowed for a maximum of 5 meters
(depending on the situation)
Minimal 1 meter vertical and maximal 12 meters vertical (depending on situation)
Determine on the base of the example calculations in Appendix A and on the base of the
table in Appendix B if the desired situation is possible. To establish this you will need to
calculate:
The effective height (this is the real difference in height between the upper side of
the appliance and the terminal)
The total horizontal extension. This is the total horizontal flue length where:
1. each 90-degree bend, which is in the horizontal area, counts for 2 meter
2. each 45-degree bend, which is in the horizontal area, counts for 1 meter
3. elbows and bends at the transition of horizontal to vertically are not to be
counted
4. the wall mounted terminal or roof terminal counts for 1 meter
3.2.1 Terminal position
Verify if the required terminal position meets the local installation regulations regarding
disturbance, good functioning and ventilation (see also appendix G).
Note:
The terminal must be located so that the outlet is not obstructed. If the flue
terminal is located within 2 meters of a footway path or where people could come
into contact with it, then a suitable terminal guard must be fitted