Replacing components
Figure 6: Removing the control panel kit
Ê Pull out the control panel kit toward you.
To install the control panel kit follow the above steps in reverse.
4.5
Replacing the chassis ID / temperature
sensor
In this server, the chassis ID/temperature sensor is located on the control panel
board. Therefore, to replace the chassis ID/temperature sensor, you must
replace the entire control panel kit (see
on page
20).
I
To enable ServerView and ServerStart to identify the system, the chassis
ID prom must be reprogrammed with the ChassisIDProm tool after the
new control panel board has been installed.
The tool can be found on the ServerSupport CD or downloaded from the
Fujitsu Siemens Computers service and support area on the Internet
(http://extranet.fujitsu-siemens.com/service/information/intelservers/tools).