USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursu- ant to Part 15 of the FCC Rules.
Page 3
® Switch Series Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AMX, AMWorks, OSCAR, AutoView, DSR, OutLook, SwitchView and XP are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners.
Page 4
Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Dangerous Voltage This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
TABL E OF CONTEN TS Table of Contents List of Figures ........................ vii List of Tables ........................ix Chapter 1: Product Overview..................1 Glossary ............................. 3 Component Overview......................... 4 The AMX switch.......................... 5 The AMX user station ........................ 5 The AMX switch IQ modules ...................... 6 UTP cables..........................
Page 6
AMX Switch Series Installer/User Guide Chapter 3: Operations ....................33 OSCAR Interface Overview ......................33 Accessing the OSCAR interface....................33 Changing the OSCAR hotkey sequence ..................34 OSCAR interface tabs ....................... 34 Target Devices ..........................35 Connection modes........................35 Accessing target devices ......................35 Setting a target device hotkey ....................
Page 7
Table of Contents Disabling Auto User Login....................... 63 Equalization tuning........................63 Deskew tuning........................... 64 Configuring the DDC table ...................... 65 Forcing a Connection to a Target Device ..................65 Forcing a connection using the OSD Command Line .............. 66 Forcing a connection from the serial port to a target device........... 67 Forcing a connection using SNMP...................
L IS T O F F IG URE S List of Figures Figure 1.1: Typical AMX Switching System Configuration .............. 5 Figure 2.2: AMX Switching System Configuration with AMIQ and AMIQ-SRL Modules....10 Figure 2.3: AMX Switching System Configuration with AMIQDM Modules........11 Figure 2.4: AMX Switching System Configuration with Redundancy..........
Page 10
AMX Switch Series Installer/User Guide Figure 3.14: Edit User Screen - Normal User................. 46 Figure 3.15: User Rights Screen ..................... 46 Figure 3.16: Edit User Screen - Admin User .................. 47 Figure 3.17: Configure Screen ......................49 Figure 3.18: Console Screen ......................50 Figure 3.19: Audio/Serial Screen (User Tab) .................
Page 11
LIST OF T A B LES List of Tables Table 3.1: Available Keyboard Layouts on the AMX User Station ..........48 Table 3.2: Available Keyboard Layouts on USB and Sun IQ Modules ........... 49 Table 3.3: PS/2 Keyboard to Sun Server ..................51 Table 3.4: Power/Sleep for USB Servers..................
Page 12
AMX Switch Series Installer/User Guide Table 1.18: IBM C2T ........................90 Table 1.19: KVM Switch ........................91 Table 1.20: Pod Switch Mode Commands..................94...
A typical AMX switching system consists of one or more AMX switches, user stations and Avocent matrix intelligent (IQ) modules. Up to three tiers of AMX switches can be cascaded to provide seamless access to a large number of target devices. Other KVM switches, including Avocent and non-Avocent branded, may also be attached in a cascaded system but do not provide seamless cascading.
Page 14
You can increase the number of target devices that users can access by creating a cascaded switching system. You can connect target devices to up to three levels of AMX or non-Avocent KVM switches. When cascading AMX switches, you can seamlessly connect to any target device from a single list in the OSCAR interface, as if all the target devices were connected to one switch.
Chapter 1: Product Overview must first select the non-Avocent switch from the OSCAR interface target list, and then connect to the target device using the methods provided by the non-Avocent KVM switch. Redundancy and scalability You may connect two AMX matrix switches to a single user station to allow redundancy and fault tolerance.
One or more AMX switches. • One or more Avocent AMX matrix user stations. • One or more Avocent IQ modules, available in several different types including the AMIQ, AMIQDM and AMIQ-SRL modules. • Unshielded Twisted Pair (UTP) cables. A typical AMX switching system configuration is illustrated in Figure 1.1.
Chapter 1: Product Overview itch AMX Sw UTP Cables 64 Servers Module User Station 16 Users Figure 1.1: Typical AMX Switching System Configuration The AMX switch The AMX switch provides the framework for the AMX switching system and is available in a variety of matrix sizes.
AMX Switch Series Installer/User Guide The AMX switch IQ modules The IQ module is the primary interface between an attached device (KVM switch, serial device or PS/2, Sun or USB server) and the AMX switching system. If the switch loses power, the target devices will continue to power the IQ modules.
To avoid potentially fatal shock hazard and possible damage to equipment, please observe the following precautions: • Do not use a 2-wire extension cord in any Avocent product configuration. • Test AC outlets at the server and monitor for proper polarity and grounding.
UTP cables for each target device and user station you plan to attach to the switching system. • One AMIQ or AMIQDM module for each server and one AMIQ-SRL module for each serial device. • AMWorks software, available by free download at www.avocent.com/support or on the installation CD included with the AMX switch.
AMX Switch Series Installer/User Guide Figure 2.2 illustrates one possible switching system configuration using AMIQ and AMIQ-SRL modules. Server with AMWorks Software AMX Switch (AMX5000 Switch Shown) AMIQ-SRL Module Target Devices AMIQ Module (PS/2 Shown) Local PC Serial Device AMX User Station...
Chapter 2: Installation Figure 2.3 illustrates another possible switching system configuration using AMIQDM modules, specialized IQ modules with dual port connectivity and audio and serial connections. Server with AMWorks Software AMX Switch (AMX5000 Switch Shown) Target Devices AMIQDM Module (PS/2 Shown) AMX User Station Local Server (AMX5130 User Station Shown)
AMX Switch Series Installer/User Guide Figure 2.4 illustrates a switching system configuration where two AMX switches are connected to a single user station, and target servers are connected to both switches using AMIQDM modules. By utilizing this connection method, you may benefit from switch redundancy in the event of a single switch failover.
Chapter 2: Installation Rack Mounting an AMX Switch A rack mounting kit is supplied with each AMX switch. You may either place the AMX switch on the rack shelf or mount the switch directly into an Electronic Industries Alliance (EIA) standard rack.
AMX Switch Series Installer/User Guide Network User Server Ports Port Ports Figure 2.6: Example of an AMX Switch Back Panel (AMX5020 Switch Shown) CAUTION: To reduce the risk of electric shock or damage to your equipment - - Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
CAUTION: This password places your AMX switch terminal in a secure mode. This password should be guarded like any network password and care should be taken to avoid forgetting or misplacing it. This password cannot be reset or recovered if lost or forgotten. Should you lose your password, please contact Avocent Technical Support for assistance.
AMX Switch Series Installer/User Guide AMX Switch (AMX5000 Switch Shown) Server Ports UTP Cable Target Devices AMIQ Module (PS/2 Shown) Target Device Figure 2.7: Connecting Target Devices to an AMX Switch (AMX5000 Switch Shown) For future reference, note the unique identifier (UID) on the back of the IQ module and the target device to which it is attached.
Chapter 2: Installation Connecting Users to the AMX Switching System Once all target devices are attached, add users by attaching user stations and peripheral devices to the AMX switching system. Figure 2.8 illustrates how to connect users to the switching system. AMX Switch (AMX5000 Switch Shown) Target Server Ports UTP Cable...
AMX Switch Series Installer/User Guide in Figure 2.8. If an appropriate port is available, the keyboard or mouse type is supported by the user station. Specialized keyboards such as Pinnacle FAK, Chyron Duet and Devlin Vizrt keyboards are connected through the PS/2 port. The Pinnacle FAK and Chyron Duet keyboards, if supported on your user station, may be selected through the OSCAR interface.
Chapter 2: Installation in the switching system. For illustrations of switching systems with a local server, see Figure 2.8 on page 17. To connect a local server to the AMX switch: Choose an appropriate IQ module and insert the connectors into the corresponding ports on the back of the server.
AMX Switch Series Installer/User Guide Network Server with AMWorks Software AMX Switch AMX Switch (AMX5000 Switch Shown) (AMX5000 Switch Shown) Target Server Ports Target Server Ports UTP Cable UTP Cable AMX User Station (AMX5130 User Station Shown) USB Keyboard and Mouse...
Multiple KVM switches can be connected to the switching system to provide access to additional target devices. You can connect target devices to up to three levels of AMX or non-Avocent KVM switches. When cascading AMX switches, you can seamlessly connect to any target device from a...
KVM switches, but to access the attached target devices you must first select the non-Avocent switch from the OSCAR interface target list, and then connect to the target device using the methods provided by the non-Avocent KVM switch. To use seamless cascading, you will need to configure the cascaded target device as Multiple Device Mode (MDM).
Chapter 2: Installation PRIMARY TIER Non-blocking Configuration 8 AMX User Stations (AMX5111 User Station Shown) AMX Switch (8 x 32, AMX5000 Switch Shown) Server Ports User Ports UTP Cabling Target Devices 4 User Paths SECONDARY TIER Blocking Configuration AMX Switch (4 x 16, AMX5030 Switch Shown) User Ports Server Ports...
AMX Switch Series Installer/User Guide Figure 2.12 illustrates a cascaded AMX switching system with a combination of blocking and non- blocking configurations. In this example, the primary switch supports eight users, and eight user paths are connected to each secondary switch, creating a non-blocking configuration. The target devices attached to the secondary tier will never be blocked and can be accessed at any time.
Page 37
Attach a UTP cable to the RJ-45 port on the IQ module. Attach the other end of the cable to an RJ-45 server port on the primary AMX switch. NOTE: When you select the non-Avocent switch from the OSCAR interface, the OSD for that switch will open and allow you to connect to attached target devices.
AMX Switch Series Installer/User Guide Installing AMWorks Software Once all users, target devices and switches have been attached and connected to the LAN, it’s best to install the AMWorks software and synchronize it with the switching system. If you have a previous AMWorks software version installed, it’s advisable to update the switching system with the most recent version of AMWorks software.
Chapter 2: Installation Place the installation CD for your new version of the AMWorks software into your CD drive, and select Setup. Follow the on-screen instructions. You may install the new version of the AMWorks software over the old version, and you may choose to keep your existing database intact. Proceed to Configuring AMWorks software.
AMX Switch Series Installer/User Guide machines through an AMX switch and nVision router combination. Broadcast engineers have full access to all servers and equipment to provide maintenance and support. In addition, all valuable equipment is secured and housed in a safe environment.
Before you begin using the AMX switching system, it’s best to update firmware to the most current version available. Check the Avocent web site at www.avocent.com/support for new firmware updates. Flash upgrades allow you to update the firmware of your AMX switch and incorporate new features into your existing switching system.
AMX Switch Series Installer/User Guide • Server port LEDs – Each LED corresponds to a server port and illuminates in green when the server or cascaded AMX switch is attached and powered up. • LAN and Power LEDs – The green LAN LINK LED illuminates when a valid connection is made to the network port of the AMX switch.
Chapter 2: Installation Figure 2.16: AMX User Station Back Panel (AMX5111 User Station Shown) • Activity status LED – The yellow LEDs blinks when the link connection is active and data is being transferred and are not lit when the link connection is inactive. •...
CHA PTER Operations OSCAR Interface Overview Use the intuitive OSCAR graphical user interface to configure the switching system and select target devices. The OSCAR interface is easily accessed and always available at the desktop. Figure 3.1 illustrates an example OSCAR interface screen. Close Button OSCAR Interface Tabs First Subscreen Button...
AMX Switch Series Installer/User Guide Changing the OSCAR hotkey sequence You can set the hotkey sequence used to launch the OSCAR interface for each user station. To change the OSCAR hotkey sequence: Press to launch the OSCAR interface. Ctrl+Ctrl Click the Console tab, then click the down arrow button to access the Configure screen.
Chapter 3: Operations The ? tab provides access to the OSCAR interface help and displays the software version and name of the user station. Target Devices Target devices attached to the switching system are displayed on the Target tab. You can select a target device in Shared, Private, Scan or Maintain connection modes.
AMX Switch Series Installer/User Guide To select a target device: Press to launch the OSCAR interface. Ctrl+Ctrl Click the Target tab. Select an access mode: Shared, Private, or Maintain. You can also select Scan to scan the switching system. See Scanning the switching system on page 41 for more information.
Chapter 3: Operations If you would like to remove all hotkey assignments, click Clear All. Click the target device you wish to set or change. Click the Change button. The Change Hotkey screen displays. Figure 3.3: Change Hotkey Screen If the selected hotkey is already assigned to a different target device, you can re-assign the selected hotkey or return to the Change Hotkey screen to select another hotkey.
AMX Switch Series Installer/User Guide Figure 3.4: Configure Screen Select Quick Switch. To save changes, click Apply. To exit the OSCAR interface, click Cancel or X. NOTE: Quick switch hotkeys only work if there is an existing connection and the OSCAR interface is not activated.
Chapter 3: Operations Setting a target flag After a connection is made to a target device, a target flag will appear briefly on screen and display the name or UID of the selected target device. Each user can configure the target flag settings according to his or her preference.
AMX Switch Series Installer/User Guide To set a hotkey – Select a hotkey from the Hotkey drop-down list. If the target flag is displayed, entering this hotkey will hide the flag. Conversely, if the target flag is hidden, entering this hotkey will display the flag.
Chapter 3: Operations Figure 3.8: Information Screen To return to the Device Admin screen, click Close. To exit the OSCAR interface, click X. Scanning the switching system You can use the Scan connection mode to monitor multiple target devices in sequence. To scan an AMX switching system: Press to launch the OSCAR interface.
AMX Switch Series Installer/User Guide Once scanning is initiated, the AMX switch will cycle through the selected target devices in alphabetical order. If the user has full access rights to the current target device and the AMX user station detects keyboard or mouse activity, scanning is suspended.
Chapter 3: Operations Users The AMX switching system can be configured to support up to 128 users. Each user is identified by a unique name and password and can be assigned full, view only or no rights to target devices attached to the AMX switch.
Enter your new password and verify it in the fields provided. Your password must be at least six characters in length. NOTE: If you lose your password, contact Avocent Technical Support for assistance. To save changes, click Apply. To exit the OSCAR interface, click Cancel or X.
Chapter 3: Operations Figure 3.13: Add User Screen Enter the name of the user in the User name field. Enter the user’s password and confirm it in the provided fields. -or- Select Allow Blank Password to enable the user to log in without entering a password. To save changes, click OK.
AMX Switch Series Installer/User Guide Select the user you wish to edit. Click the Edit User button. The Edit User screen displays. Figure 3.14: Edit User Screen - Normal User You may change the user’s name or password or allow blank passwords.
Chapter 3: Operations To change a user’s access rights to multiple target devices, press and hold the key while Ctrl you individually select the target devices that you wish to be controlled externally. Alternately, if you wish to select a group of target devices in sequence, click the first target device in the sequence, press and hold the key and select the last target device to highlight the group.
AMX Switch Series Installer/User Guide Configuring Keyboard Settings You can use keyboard layouts from multiple countries and regions in the AMX switching system. The AMX switch also supports multiple keyboard types, including any PS/2, USB or Sun keyboard, Pinnacle FAK or Chryon Duet.
Chapter 3: Operations Figure 3.17: Configure Screen Select a keyboard layout from the Layout drop-down menu. To save changes, click Apply. To exit the OSCAR interface, click Cancel or X. Device When connecting a non-U.S. 13W3, VGA Sun or USB server to an AMX switching system, you must manually set the keyboard for that target device.
AMX Switch Series Installer/User Guide Keyboard type If you connected a PS/2, USB or Devlin Vizrt keyboard to the user station, you will not have to change the keyboard type. If you connected a Pinnacle FAK or Chyron Duet keyboard to the user station, complete the following steps to set the keyboard type.
Chapter 3: Operations -or- Click Cancel to exit the OSCAR interface without saving changes If you connected a Pinnacle FAK keyboard, complete the following steps: Click the Admin tab. Select the target device that will be running software that requires Pinnacle FAK support. Click Edit device.
AMX Switch Series Installer/User Guide Using the Power/Sleep key Table 3.4 shows the Power/Sleep key on USB servers for Sun and PS/2 keyboards. Sun keyboards have a Power key used to power the workstation. Some PS/2 keyboards have a Sleep key to place the server in a stand-by or power saving mode.
Chapter 3: Operations Figure 3.19: Audio/Serial Screen (User Tab) Click the checkboxes to enable or disable speakers, microphone or serial emulation. To save changes, click Apply. To exit the OSCAR interface, click Cancel or X. To view and modify admin audio and serial settings for a device: Press Ctrl+Ctrl to launch the OSCAR interface.
AMX Switch Series Installer/User Guide Figure 3.20: Audio/Serial Screen (Admin Tab) NOTE: The first time this screen is accessed, the Audio out, Audio in and Serial checkboxes will be checked (enabled) for devices that are multimedia-capable. Click the Audio out (speakers), Audio in (mic) or Serial checkboxes to enable or disable as required for the selected device.
Chapter 3: Operations Figure 3.21: Information Screen Click Close to return to the Device Admin screen. Click Cancel or X to exit the OSCAR interface. To modify IQ module properties, see Setting Device Properties on page 58. User Stations You can configure settings specific to your user station by accessing the Console tab. To view the user station status: Press Ctrl+Ctrl...
AMX Switch Series Installer/User Guide Locking user station settings The Administrator may lock specific settings for each user station. Lockdown settings cannot be accessed by other users. See Administering security settings on page 45 for more information. To enable lockdown settings: Press to launch the OSCAR interface.
Chapter 3: Operations Persistent mode Persistent mode allows a user station to attempt to re-establish a connection to the last known target. When you enable persistent mode, the currently displayed target UID and connection type is stored as the persistent mode settings. If there is no established connection when you enable persistent mode, the settings of the next successful connection are stored.
AMX Switch Series Installer/User Guide Figure 3.25: Inactivity Screen To hide the user station OSD after the specified period of inactivity time has elapsed, enable Screen Saver. To log your username out of the switching system after the specified period of inactivity time has elapsed, select Logout.
Chapter 3: Operations Figure 3.26: Device Admin Screen A list of devices, including target devices and IQ modules, will display. In the Find field, click name to search by name. - or - Click UID to search by UID. NOTE: If a name has not been set for the device, a default name will be displayed. Clicking the Reset name button sets the device name to its default name.
Page 72
Click the Edit Device button. The Edit Device screen displays. Type a new name (1-15 characters) for the device in the Name field. From the Target drop-down list, select the cascaded Avocent KVM switch to which the IQ module is attached.
Chapter 3: Operations Figure 3.28: Edit Device Screen (Seamless Configuration) In the MDM Switch area, select the number of ports on the cascaded KVM switch from the Ports drop-down list. In the MDM Switch area, select the hotkey sequence of the cascaded KVM switch from the Hotkey drop-down list.
AMX Switch Series Installer/User Guide Accessing the Command Line Table 4.3 provides a list of hotkey sequences used to activate the Command Line. The default Command Line hotkey sequence is the key pressed and held, followed by the NumLock Minus key.
Chapter 3: Operations To reset the keyboard and mouse: Press the default Command Line hotkey sequence to display the Command Line. Type and press to reset the keyboard. Enter - or - Type and press to reset the mouse. Enter Disabling Auto User Login Auto User Login at the user station can only be enabled by the Administrator, but it can be disabled by any user.
AMX Switch Series Installer/User Guide If you are currently connected to a target device, the offset values will be immediately applied to the video signal. If you wish to save the current equalization tuning settings, click Save. The equalization tuning settings will be permanently stored on the user station and will be applied to the video signal each time you connect to a target device.
DDC table. CAUTION: If you are unsure of what DDC table is needed for your system, do not change the DDC table setting. Contact your system administrator or Avocent Technical Support for more information about configuring the DDC table. To configure the DDC table: Press the default Command Line hotkey sequence to display the Command Line.
AMX Switch Series Installer/User Guide You can force a connection using any of the following methods: • Forcing a connection using the Command Line • Forcing a connection using Serial Force mode • Forcing a connection using SNMP Guidelines NOTE: The following guidelines do not apply when forcing a connection using SNMP.
Chapter 3: Operations Type and press to force the target user fc ‘[TargetUserStationName]’ ‘[servername]’ Enter station to connect to the specified target device. -or- Type and press to force the target user station to fd ‘[TargetUserStationName]’ Enter disconnect from the connected target device. Forcing a connection from the serial port to a target device Once Serial Force mode is enabled, a serial device attached to the host user station can send a force connect or disconnect command to that user station.
AMX Switch Series Installer/User Guide From the attached serial device, send an fc ‘[TargetUserStationName]’ ‘[servername]’ command to the host user station followed by a carriage return character . This will [0x0D] force the target user station to connect to the specified target device.
AMX switch, refer to the specific MIB file called AMX-MIB. This MIB file is available on the AMWorks software CD. You can also download the AMX-MIB file by visiting www.avocent.com/support and clicking Product Upgrades.
CHA PTER Terminal Operations Accessing the Terminal Menu You can configure an AMX switch at the unit level through the Terminal port. All terminal commands are accessed through a terminal or PC running terminal emulation software. To access the Terminal Applications menu: Connect a terminal or PC running terminal emulation software (such as HyperTerminal) to the configuration port on the AMX switch using the supplied null modem cable.
CAUTION: This password places your AMX switch terminal in a secure mode. This password should be guarded like any network password and care should be taken to avoid forgetting or misplacing it. This password cannot be reset or recovered if lost or forgotten. Should you lose your password, please contact Avocent Technical Support for assistance.
Page 85
Chapter 4: Terminal Operations SNMP Configuration The SNMP Configuration option on the Terminal Applications menu enables you to specify the following parameters for SNMP processing: • Enabling and disabling SNMP • Defining read, write and trap community names • Defining and deleting up to four trap destination IP addresses •...
AMX Switch Series Installer/User Guide Managing AMX switch objects with SNMP Using SNMP, you can monitor and manage MIB (Management Information Base) objects specific to the AMX switch. Refer to Table 4.2 for a description of the AMX system MIB object groups.
A P P EN D IC ES Appendices Appendix A: Technical Specifications Table 1.1: AMX5000 Switch Specifications Server Ports Number Connectors RJ-45 AMX switch interconnect User Ports Number Connectors RJ-45 AMX switch interconnect Network Connection Number Type Ethernet, 10BaseT, 100BaseT Connector RJ-45 Terminal Port...
AMX Switch Series Installer/User Guide Table 1.2: AMX5010 Switch Specifications Server Ports Number Connectors RJ-45 AMX switch interconnect User Ports Number Connectors RJ-45 AMX switch interconnect Network Connection Number Type Ethernet, 10BaseT, 100BaseT Connector RJ-45 Terminal Port Number Type RS-232 serial...
Appendices Table 1.3: AMX5020 Switch Specifications Server Ports Number Connectors RJ-45 AMX switch interconnect User Ports Number Connectors RJ-45 AMX switch interconnect Network Connection Number Type Ethernet, 10BaseT, 100BaseT Connector RJ-45 Terminal Port Number Type RS-232 serial Connector DB9 male Mechanical H x W x D 43 x 432 x 351 mm 1 U form factor (1.7 x 17 x 13.8 in)
AMX Switch Series Installer/User Guide Table 1.4: AMX5030 Switch Specifications Server Ports Number Connectors RJ-45 AMX switch interconnect User Ports Number Connectors RJ-45 AMX switch interconnect Network Connection Number Type Ethernet, 10BaseT, 100BaseT Connector RJ-45 Terminal Port Number Type RS-232 serial...
Appendices Table 1.5: AMX5130 User Station Specifications Server Ports Number Connectors RJ-45 AMX switch interconnect User Ports Number PS/2: 2; VGA video: 1; USB: 2; Audio: 2, Serial: 1 Type PS/2, VGA video, USB, Audio and Serial PS/2: 6-pin miniDIN, PS/2 keyboard and mouse; VGA video:15HDD female; Connectors USB: Type A;...
AMX Switch Series Installer/User Guide Table 1.6: AMX5111 and AMX5121 User Station Specifications Server Ports Number Connectors RJ-45 AMX switch interconnect User Ports Number PS/2: 2; VGA video: 1; USB: 2; Serial: 1 Type PS/2, VGA video, USB, and Serial PS/2: 6-pin miniDIN, PS/2 keyboard and mouse;...
AMX Switch Series Installer/User Guide Appendix B: Using AMIQ-SRL Modules The AMIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be viewed from the AMX51xx user station. The actual serial data is not accessed, but is merely displayed. All serial data coming from the target device is displayed in a VT100 window, placed into a video buffer and sent to the AMX51xx user station as though it came from a VGA target device.
Page 97
Appendices • Background: This option changes the screen’s background color. The currently-selected color displays in the option line as it is changed. Available colors are Black, Grey, Light Grey, White, Yellow, Green, Teal, Cyan, Blue, Dark Blue, Purple, Pink, Orange Red, Maroon and Brown.
Page 98
AMX Switch Series Installer/User Guide Repeat steps 2 and 3 to modify additional values. Press to save your changes and exit the Configuration Screen. Enter - or - Press to exit the Configuration Screen without saving the changes. Creating an AMIQ-SRL module macro Pressing the Page Down key when the Configuration Screen is displayed will provide access to the Macro Configuration screen.
Appendices Press each key to perform the action described in the following table. Table 1.10: History Mode Control Keys History Mode Action Home Move to the top of the buffer. Move to the bottom of the buffer. Page Up Move up one buffer page. Page Down Move down one buffer page.
AMX Switch Series Installer/User Guide Table 1.11: AMIQ-SRL Module Pinouts (Continued) Host Signal DB9-F Signal Flow SRL Signal Name/Description Name/Description CTS - Clear to Send Out of SRL RTS - Request to Send N/C - Not Connected N/C - Not Connected...
AMX Switch Series Installer/User Guide Table 1.15: AV2000R, AV1000R, AV2000 or DSR Switch (Continued) The Print Screen key is not operational for a target device Hotkeys connection Required: Setting the display order of the target device list to “Port” Unit Settings Recommended: Setting the OSD screen display time to 2 seconds Table 1.16: OutLook ES Switch...
If the user station needs to be updated, visit www.avocent.com to download the latest firmware version. Use the AMWorks Java-based system administration tool to Flash upgrade your AMX switching system with the new firmware version.
Appendices connected to the user station. In this example, Monitor A will always display video from the local target device attached to the user station. Monitor B will always display video from a selected remote target device attached to the AMX switch. By using the pod switch hotkey, keyboard and mouse control can be “switched”...
AMX Switch Series Installer/User Guide Enabling Pod Switch mode Use the OSD Command Line to enable or disable Pod Switch mode. Table 1.20 lists Pod Switch mode commands that may be entered at the Command Line. Table 1.20: Pod Switch Mode Commands...
Page 107
Appendices NOTE: If the user station has been configured to display the Target Flag, the local target device Target Flag will display as “Pod Switch On” when a pod switch is made. For more information about configuring the Target Flag, see Setting a target flag on page 39.
AMX Switch Series Installer/User Guide Appendix E: Troubleshooting One or two colors are missing on a server or a user station • Check the VGA connection between the user station and the monitor. • Check the VGA connection between the IQ module and the server.
Page 109
Appendices The console port on the AMX switch has locked up • Check the terminal emulation software settings to ensure accuracy. • Restart terminal emulation software and start again. • Power cycle the AMX switch and start again. The OSCAR interface does not display unless a switch is made •...
Page 110
AMX Switch Series Installer/User Guide • Once you enter the pod switch hotkey, there may be a slight delay before you can control the target device. This will allow the keyboard and mouse settings to be synchronized. For example, the local target device may have Caps Lock on, while the remote target device may have Caps Lock off.
Appendix F: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service. To resolve an issue: Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined.
Page 112
AMX Switch Series Installer/User Guide...
I N D E X Index configuration ID 14, 72 connecting local server 18 AMIQ module connecting serial devices 16 see IQ module connecting target devices 15 AMIQDM module connecting users 17 see IQ module definition of 3 AMIQ-SRL module expansion capability 2 see IQ module features and benefits 1–3...
Page 114
AMX Switch Series Installer/User Guide status 55 Deskew tuning 64 target user station 65 Devlin Vizrt keyboard 2, 18, 50 Audio data emulation Digital Data Channel 6 about 2 DDC table 65 Administrator settings 53 user settings 52 Edit Device screen User tab 34 settings for KVM switch 89–91...
Page 116
AMX Switch Series Installer/User Guide Pod switch mode configuration 92 OSCAR interface enabling 94 ? tab 35 troubleshooting 95 about 3, 33 Power considerations 13 Admin tab 34 Power/Sleep command 52 Command Line 61 Private mode 35 Console tab 34...
Page 117
Index Shared mode 35, 66 SNMP configuration 73 Simple Network Management Protocol SNMP processing 73 about 3 Trap 73 adding an SNMP user 69 Troubleshooting 96 configuration 73–74 SNMP Uninterruptible Power Supply (UPS) 7 see Simple Network Management Protocol Unit definition of 4 Target devices User paths 22–24...
Page 120
® de la série AMX Guide d’installation et d’utilisation Avocent, le logo Avocent, The Power of Being There, AMX, AMWorks, OSCAR, AutoView, DSR, Outlook, SwitchView et XP sont des marques déposées d’Avocent Corporation ou de ses filiales. Toutes les autres marques sont la propriété...
Page 121
Instructions Ce symbole est destiné à attirer votre attention sur la présence de consignes importantes liées au fonctionnement et à la maintenance (entretien) dans la documentation accompagnant le matériel. Tension dangereuse Ce symbole est destiné à vous avertir de la présence de « tensions dangereuses » non isolées à l’intérieur de l’appareil pouvant être suffisamment élevées pour constituer un risque de choc électrique pour les individus.
Page 122
T A B L E D E S MAT I È R ES Table of Contents List des Figures......................vii List des Tables ........................ ix Chapitre 1 : Présentation du produit................1 Glossaire ............................4 Présentation des composants......................4 Le commutateur AMX ......................... 5 La console utilisateur AMX ......................
Page 123
Le guide d’installation et d’utilisation de la série AMX Chapitre 3 : Opérations ....................33 Présentation de l’interface OSCAR ....................33 Accès à l’interface OSCAR....................... 33 Modification de la séquence de raccourci clavier d’OSCAR........... 34 Onglets de l’interface OSCAR ....................34 Équipements cibles ..........................
Page 124
Table des matières Désactivation de la connexion automatique utilisateur ............64 Réglage de l’égalisation ......................64 Réglage du réalignement ......................65 Configuration du tableau DDC ....................66 Connexion forcée à un équipement cible ..................67 Connexion forcée à l’aide d’une ligne de commande de l’OSD ..........68 Connexion forcée à...
Page 125
Le guide d’installation et d’utilisation de la série AMX...
Page 126
L I S T E D E S F I G U R E S List of Figures Figure 1.1 : Configuration classique du système de commutation AMX ......... 5 Figure 2.2 : Configuration de système de commutation AMX avec modules AMIQ et AMIQ-SRL..................
Page 127
viii Le guide d’installation et d’utilisation de la série AMX Figure 3.10 : Écran User......................... 43 Figure 3.11 : Écran User......................... 44 Figure 3.12 : Écran User Admin ..................... 45 Figure 3.13 : Écran Add User ......................46 Figure 3.14 : Écran Edit User - Utilisateur ..................47 Figure 3.15 : Écran User Rights .....................
Page 128
LISTE DES T ABLEAUX List of Tables Tableau 3.1 : Configurations clavier disponibles sur la console utilisateur AMX ......49 Tableau 3.2 : Configurations clavier disponibles sur les modules IQ USB et Sun ......50 Tableau 3.3 : Clavier PS/2 et serveur Sun ..................52 Tableau 3.4 : Alimentation/Veille pour les serveurs USB ...............
Page 129
Le guide d’installation et d’utilisation de la série AMX Tableau 1.18 : IBM C2T ........................91 Tableau 1.19 : Commutateur KVM....................92 Tableau 1.20 : Commandes du mode de commutation clavier-souris..........95...
Page 130
Un système de commutation AMX typique comprend un ou plusieurs commutateurs AMX, des consoles utilisateur et des modules intelligents à matrice (IQ) d’Avocent. Il est possible de monter jusqu’à trois commutateurs AMX en cascade afin d’obtenir un accès continu à un grand nombre d’équipements cibles.
Page 131
Le guide d’installation et d’utilisation de la série AMX Authentification LDAP des utilisateurs Le commutateur AMX est compatible avec le mode LDAP (Lightweight Directory Access Protocol) d’authentification des utilisateurs. Ce mode utilise le serveur d’annuaires Active Directory pour l’authentification des noms d’utilisateurs et des mots de passe. Fonction avancée de compensation des mouvements vidéo Les consoles utilisateur AMX et les modules IQ comportent une fonction avancée de compensation de mouvements vidéo qui offre une qualité...
Vous pouvez connecter jusqu’à trois niveaux de commutateurs KVM AMX ou d’une autre marque qu’Avocent à des équipements cibles. Lors du montage de commutateurs AMX en cascade, vous pouvez vous connecter en continu à tout équipement cible depuis une seule liste de l’interface OSCAR, comme si tous les équipements...
AMX ; • une ou plusieurs consoles utilisateur à matrice AMX d’Avocent ; • un ou plusieurs modules IQ d’Avocent, disponibles en plusieurs modèles, y compris les modules AMIQ, AMIQDM et AMIQ-SRL ; • des câbles UTP.
Chapitre 1 : Présentation du produit Commutateur AMX Câbles UTP 64 serveurs Module IQ Console utilisateur AMX 16 utilisateurs Figure 1.1 : Configuration classique du système de commutation AMX Le commutateur AMX Le commutateur AMX, qui se trouve à la base même du système de commutation AMX, est disponible en plusieurs tailles de matrices.
Le guide d’installation et d’utilisation de la série AMX Les modules IQ pour commutateur AMX Le module IQ constitue l’interface principale entre l’équipement relié (commutateur KVM, équipement série ou serveur PS/2, Sun ou USB) et le système de commutation AMX. En cas de coupure d’alimentation du commutateur, les équipements cibles continuent d’alimenter les modules IQ.
Afin d’éviter tout risque de choc mortel et tout dommage matériel, prenez les précautions suivantes : • N’utilisez jamais de rallonge à 2 fils avec les produits Avocent. • Vérifiez la polarité et la masse des prises de courant alternatif du serveur et du moniteur.
Page 137
Le guide d’installation et d’utilisation de la série AMX...
Un module de type AMIQ ou AMIQDM pour chaque serveur et un module de type AMIQ- SRL pour chaque équipement série. • Le logiciel AMWorks, qui est disponible soit par téléchargement gratuit sur le site www.avocent.com/support, soit sur le CD d’installation inclus avec le commutateur AMX.
Page 139
Le guide d’installation et d’utilisation de la série AMX La Figure 2.2 illustre l’une des configurations possibles du système de commutation à l’aide de modules AMIQ et AMIQ-SRL. Réseau Serveur équipé du logiciel AMWorks Commutateur AMX (commutateur AMX5000 illustré) Module AMIQ- Équipements cibles Module AMIQ (type...
Page 140
Chapitre 2 : Installation La Figure 2.3 illustre une autre configuration possible du système de commutation qui comporte des modules AMIQDM, des modules IQ spéciaux à double voie de connexion et des connexions audio et série. Serveur équipé du logiciel Réseau AMWorks Commutateur AMX (commutateur AMX5000 illustré)
Page 141
Le guide d’installation et d’utilisation de la série AMX La Figure 2.4 illustre une configuration du système de commutation où deux commutateurs AMX sont connectés à une seule console utilisateur et des serveurs cibles sont reliés aux deux commutateurs à l’aide de modules AMIQDM. Cette méthode de connexion vous permet de profiter d'une redondance de commutateurs offrant une sécurité...
Chapitre 2 : Installation Montage en rack d’un commutateur AMX Le commutateur AMX est livré avec un kit de montage en rack. Vous pouvez choisir d’installer le commutateur AMX sur l’une des étagères de votre rack ou de le monter directement dans un rack conforme à...
Page 143
Le guide d’installation et d’utilisation de la série AMX Voie Voies utilisateur Voies serveur réseau Figure 2.6 : Exemple de panneau arrière de commutateur AMX (commutateur AMX5020 illustré) ATTENTION : Pour éviter d’endommager votre matériel et écarter tout risque d’électrocution : - Ne retirez pas la prise de terre, elle constitue un élément de sécurité...
Veillez à ne pas l’oublier ni l’égarer. Ce mot de passe ne peut pas être réinitialisé ou retrouvé s’il est perdu ou oublié. En cas de perte de votre mot de passe, contactez le service d’assistance technique d’Avocent. Saisissez pour quitter le menu Console du système de commutation AMX.
Page 145
Le guide d’installation et d’utilisation de la série AMX Commutateur AMX (commutateur AMX5000 illustré) Voies serveur Câble UTP Équipements cibles Module AMIQ (type PS/2 illustré) Équipement cible Figure 2.7 : Connexion des équipements cibles à un commutateur AMX (commutateur AMX5000 illustré) Notez l’identifiant unique (UID) situé...
Chapitre 2 : Installation Connexion des utilisateurs au système de commutation AMX Une fois que tous les équipements cibles sont reliés, connectez les consoles utilisateur et les périphériques au système de commutation AMX afin d’ajouter les utilisateurs. La Figure 2.8 illustre la façon dont les utilisateurs doivent être connectés au système de commutation.
Page 147
Le guide d’installation et d’utilisation de la série AMX indiquées par des symboles comme illustré par la Figure 2.8. Si une voie appropriée est disponible, alors le type de clavier ou de souris correspondant est compatible avec la console utilisateur. Les claviers spécialisés tels que FAK de Pinnacle, Duet de Chyron et Vizrt de Devlin sont connectés à...
Chapitre 2 : Installation Connexion d’un serveur local au système de commutation AMX Une fois que les consoles utilisateur sont toutes connectées au système de commutation AMX, vous pouvez relier un serveur local accessible depuis la console utilisateur à laquelle il est relié, mais non par d’autres utilisateurs du système de commutation.
Le guide d’installation et d’utilisation de la série AMX Réseau Serveur équipé du logiciel AMWorks Commutateur AMX Commutateur AMX (commutateur AMX5000 illustré) (commutateur AMX5000 illustré) Voies des serveurs cibles Voies des serveurs cibles Câble UTP Câble UTP Console utilisateur AMX (console utilisateur AMX5130 illustrée) Clavier et souris USB Voies souris et...
Page 150
Chapitre 2 : Installation Commutateur AMX Module AMIQDM Serveur Commutateur Figure 2.10 : Connectivité à voie double par module AMIQDM Connexion d’un module AMIQDM avec sortie à voie double : Coupez l’alimentation de l’équipement cible. Reliez les connecteurs clavier, écran, souris, audio et série du module AMIQDM aux voies correspondantes à...
à des équipements cibles supplémentaires. Vous pouvez connecter jusqu’à trois niveaux de commutateurs KVM AMX ou d’une autre marque qu’Avocent à des équipements cibles. Lors du montage de commutateurs AMX en cascade, vous pouvez vous connecter en continu à tout équipement cible depuis une seule liste de l’interface OSCAR, comme si tous les équipements...
Page 152
Chapitre 2 : Installation La Figure 2.11 donne un exemple de configuration bloquante dans un système de commutation AMX. Dans cet exemple, un commutateur AMX à quatre utilisateurs est monté en cascade avec un commutateur AMX à huit utilisateurs. Les équipements cibles reliés au commutateur primaire ne seront jamais bloqués et les utilisateurs peuvent y accéder à...
Page 153
Le guide d’installation et d’utilisation de la série AMX La Figure 2.12 illustre un système de commutation AMX en cascade associant les configurations bloquante et non-bloquante. Dans cet exemple, le commutateur primaire est compatible avec huit utilisateurs et huit chemins utilisateur sont connectés à chaque commutateur secondaire, ce qui constitue une configuration non-bloquante.
Page 154
Reliez l’une des extrémités d’un câble UTP à la voie RJ-45 du module IQ. Reliez l’autre extrémité du câble à une voie serveur RJ-45 du commutateur AMX primaire. NOTA : Lorsque vous sélectionnez le commutateur de marque autre qu’Avocent sur l’interface OSCAR, la fenêtre correspondante s’ouvre et vous permet de vous connecter aux équipements reliés.
Le guide d’installation et d’utilisation de la série AMX Installation du logiciel AMWorks Une fois que tous les utilisateurs, équipements cibles et commutateurs sont reliés et connectés au réseau LAN, il convient d’installer le logiciel AMWorks et de le synchroniser avec le système de commutation.
Chapitre 2 : Installation Continuez en suivant les instructions fournies ci-dessus concernant l’installation initiale du logiciel AMWorks. Passage de la version 4.x.x du logiciel AMWorks (ou d’une version ultérieure) à une version supérieure : Assurez-vous que les informations de base de données diffusées dans le système de commutation sont correctes en utilisant la commande Synchronize System Database parmi les options d’installation du logiciel AMWorks actuel.
Le guide d’installation et d’utilisation de la série AMX version du firmware, référez-vous au programme d’aide en ligne du logiciel AMWorks. Après avoir effectué la mise à jour du firmware, passez à l’étape 4. NOTA : Si les commutateurs AMX ne possèdent pas la dernière version du firmware, la synchronisation des bases de données du système risque d’échouer.
Vous trouverez les mises à jour du firmware sur le site d’Avocent, à l’adresse www.avocent.com/support. Les mises à jour Flash vous permettent de mettre à jour le firmware du commutateur AMX et d’ajouter de nouvelles...
Le guide d’installation et d’utilisation de la série AMX fonctionnalités à votre système de commutation. Pour de plus amples informations concernant les mises à jour Flash, y compris les méthodes de vérification de la version du firmware, référez-vous au programme d’aide en ligne du logiciel AMWorks. NOTA : Vous devez utiliser le logiciel AMWorks pour la mise à...
Chapitre 2 : Installation Voyant d’alimentation Voyant d’activité Figure 2.15 : Panneau avant de la console utilisateur AMX • Voyant d’alimentation : le voyant du haut s’allume lorsque l’alimentation est connectée et s’éteint lorsqu’il n’y a pas d’alimentation. • Voyant d’activité : le voyant du bas clignote lorsque l’interface OSCAR est affichée et s’allume lorsque la connexion entre la console utilisateur AMX et un module AMIQ ou AMIQDM ou un commutateur AMX est correctement établie.
Page 161
Le guide d’installation et d’utilisation de la série AMX Voyants de connexion/activité Voyant d’alimentation Figure 2.17 : Modules IQ avec voyants (module AMIQDM illustré) • Voyant d’alimentation : le voyant vert d’alimentation s’allume lorsqu’une alimentation électrique est fournie. En cas de coupure d’alimentation du module AMIQ-SRL, l’interface série ne génère pas d'interruption série de l’équipement relié.
CHAPITRE Opérations Présentation de l’interface OSCAR Utilisez l’interface utilisateur graphique intuitive OSCAR pour configurer le système de commutation et sélectionner les équipements cibles. L’interface OSCAR est facile d’accès et constamment disponible sur le bureau. La Figure 3.1 fournit un exemple d’écran de l’interface OSCAR.
Le guide d’installation et d’utilisation de la série AMX Modification de la séquence de raccourci clavier d’OSCAR Vous pouvez choisir la séquence de raccourci clavier utilisée pour lancer l’interface OSCAR sur chaque console utilisateur. Modification de la séquence de raccourci clavier d’OSCAR : Appuyez deux fois sur pour lancer l’interface OSCAR.
Chapitre 3 : Opérations • Users Admin : cet écran permet à l’administrateur d’ajouter, de modifier et de supprimer des utilisateurs, d’attribuer des droits d’accès à chaque équipement cible et de forcer la connexion utilisateur. Pour plus d’informations concernant la gestion des comptes utilisateur, reportez- vous à...
Le guide d’installation et d’utilisation de la série AMX Maintain Utilisez le mode Maintain lorsque vous souhaitez rester connecté à un équipement cible pendant son redémarrage ou sa maintenance. Lorsqu’il est sélectionné en mode Maintain, l’équipement cible reste en contact avec le commutateur tout au long du cycle de redémarrage. NOTA : Il n’est pas possible de partager l’accès aux équipements cibles en mode Maintain.
Page 166
Chapitre 3 : Opérations Figure 3.2 : Écran Server Hotkey Saisissez le nom de l’équipement cible dont vous souhaitez configurer ou modifier le raccourci clavier. Une liste d’équipements cibles s’affiche. Pour afficher la liste d’équipements cibles dans l’ordre alphabétique, cliquez sur Name. Pour afficher la liste d’équipements cibles dans l’ordre de leurs raccourcis clavier, cliquez sur Hotkey.
Le guide d’installation et d’utilisation de la série AMX 10. Cliquez sur OK pour enregistrer les modifications. Pour quitter l’interface OSCAR, cliquez sur le bouton Cancel ou X. Configuration d’un raccourci clavier de commutation rapide pour équipements cibles Un raccourci clavier de commutation rapide vous permet de vous connecter rapidement aux équipements cibles en utilisant une séquence de raccourci clavier correspondant à...
Chapitre 3 : Opérations Figure 3.5 : Écran Configure Activation du raccourci clavier de commutation locale : Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. Cliquez sur l’onglet Console puis cliquez sur le bouton fléché « bas » afin d’afficher l’écran Configure.
Page 169
Le guide d’installation et d’utilisation de la série AMX Figure 3.6 : Écran Target Flag Configurez les paramètres de l’indicateur d’équipement cible comme souhaité. Pour configurer les informations : sélectionnez l’option Name pour afficher le nom de l’équipement cible relié sur l’indicateur. -ou- Sélectionnez UID pour afficher l’identifiant unique de l’équipement cible connecté...
Chapitre 3 : Opérations Figure 3.7 : Écran Set Position Pour déplacer l’indicateur d’équipement cible, cliquez sur la barre de titre de l’écran Set Position et déplacez-la vers l’emplacement souhaité. Lorsque l’indicateur est à l’emplacement souhaité, cliquez sur le bouton X pour fixer la position et revenir à...
Le guide d’installation et d’utilisation de la série AMX Balayage du système de commutation Vous pouvez utiliser le mode de connexion Scan afin de passer en revue plusieurs équipements cibles les uns après les autres. Balayage d’un système de commutation AMX : Appuyez deux fois sur pour lancer l’interface OSCAR.
Chapitre 3 : Opérations Interruption du balayage du système de commutation : Appuyez deux fois sur . L’écran de l’onglet Target réapparaît. Ctrl Cliquez sur le bouton Stop. Cliquez sur Close ou sur X pour quitter l’interface OSCAR. Modification de la durée d’affichage de balayage : NOTA : En mode verrouillé, aucun des champs de l’écran n’est actif à...
Page 173
Saisissez votre nouveau mot de passe dans le champ approprié ainsi que dans le champ de confirmation. Celui-ci doit comporter au moins six caractères. NOTA : En cas de perte de votre mot de passe, contactez le service d’assistance technique d’Avocent. Cliquez sur Apply pour enregistrer les modifications. Pour quitter l’interface OSCAR, cliquez...
Chapitre 3 : Opérations Déconnexion Déconnexion du système de commutation AMX : Appuyez deux fois sur pour lancer l’interface OSCAR. Ctrl Cliquez sur l’onglet User. Cliquez sur Log out. L’interface OSCAR se déconnecte du système de commutation et se ferme automatiquement. Gestion de la base de données utilisateur Pour gérer la base de données des utilisateurs, vous devez être connecté...
Le guide d’installation et d’utilisation de la série AMX Figure 3.13 : Écran Add User Saisissez le nom d’utilisateur dans le champ User name. Saisissez le mot de passe de l’utilisateur dans le champ Password puis dans le champ Confirm password.
Page 176
Chapitre 3 : Opérations Modification d’un utilisateur : Appuyez deux fois sur pour lancer l’interface OSCAR. Ctrl Cliquez sur l’onglet Admin. Cliquez sur le bouton fléché « bas » pour afficher l’écran User Admin. Sélectionnez l’utilisateur à modifier. Cliquez sur le bouton Edit user. L’écran Edit User s’affiche. Figure 3.14 : Écran Edit User - Utilisateur Vous pouvez modifier le nom d’utilisateur ou le mot de passe, ou autoriser un mot de passe vide.
Page 177
Le guide d’installation et d’utilisation de la série AMX Pour modifier les droits d’accès d’un utilisateur à un seul équipement cible, cliquez dessus dans la liste des équipements disponibles. Sélectionnez le niveau d’accès approprié : none, view ou full. -ou- Pour modifier les droits d’accès d’un utilisateur à...
Chapitre 3 : Opérations Si aucun mot de passe n’a été attribué à admin, créez-en un maintenant en saisissant un mot de passe dans les champs Password et Confirm Password. Cochez la case Force User Login pour forcer tous les utilisateurs à se connecter à l’aide d’un nom et d’un mot de passe.
Le guide d’installation et d’utilisation de la série AMX Figure 3.17 : Écran Configure Sélectionnez une configuration de clavier dans la liste déroulante Layout. Cliquez sur Apply pour enregistrer les modifications. Pour quitter l’interface OSCAR, cliquez sur le bouton Cancel ou X. Équipement Si vous connectez un serveur qui n’est pas de type U.S.
Chapitre 3 : Opérations Type de clavier Si vous avez connecté un clavier PS/2, USB, Sun ou Vizrt de Devlin à la console utilisateur, vous n’aurez pas à modifier le type de clavier. Si vous avez connecté un clavier FAK de Pinnacle ou Duet de Chyron à...
Le guide d’installation et d’utilisation de la série AMX Cliquez sur Apply pour enregistrer les modifications. -ou- Cliquez sur Cancel pour quitter l’interface OSCAR sans enregistrer les modifications. Si vous avez branché un clavier FAK de Pinnacle, procédez de la façon suivante : Cliquez sur l’onglet Admin.
Chapitre 3 : Opérations Tableau 3.3 : Clavier PS/2 et serveur Sun (suite) Ouvrir / (clavier) Silence Coller - (clavier) Vol - Coller + (clavier) Vol + Utilisation de la touche Alimentation/Veille Le Tableau 3.4 indique les touches équivalentes à la touche Alimentation/Veille sur un serveur USB équipé...
Page 183
Le guide d’installation et d’utilisation de la série AMX Visualisation et modification des paramètres audio et série d’un utilisateur : ATTENTION : L’utilisation d’une source de données audio réglée sur un volume élevé peut endommager votre système auditif. Appuyez deux fois sur pour lancer l’interface OSCAR.
Chapitre 3 : Opérations Figure 3.20 : Écran Audio/Serial (onglet Admin) NOTA : La première fois que cet écran est affiché, les cases à cocher Audio out, Audio in et Serial sont cochées (activées) pour les équipements compatibles avec des fonctionnalités multimédia. Cochez/décochez les cases Audio out (haut-parleurs), Audio in (micro) ou Serial afin d’activer ou de désactiver ces fonctionnalités pour l’équipement sélectionné.
Le guide d’installation et d’utilisation de la série AMX Figure 3.21 : Écran Information Cliquez sur Close pour revenir à l’écran Device Admin. Cliquez sur Cancel ou sur X pour quitter l’interface OSCAR. Pour modifier les propriétés des modules IQ, reportez-vous à la section Configuration des propriétés des équipements à...
Chapitre 3 : Opérations Verrouillage des paramètres de la console utilisateur L’administrateur peut verrouiller certains paramètres pour chaque console utilisateur. Aucun autre utilisateur ne peut accéder aux paramètres verrouillés. Reportez-vous à la section Administration des paramètres de sécurité à la page 46 pour de plus amples informations. Verrouillage des paramètres : Appuyez deux fois sur pour lancer l’interface OSCAR.
Le guide d’installation et d’utilisation de la série AMX connexion à chaud. Saisissez le nom d’utilisateur et le mot de passe dans les champs appropriés pour spécifier quel utilisateur doit être automatiquement connecté. N’importe quel utilisateur peut désactiver la connexion automatique utilisateur en saisissant sur la ligne de commande.
Chapitre 3 : Opérations Paramètres d’inactivité de la console utilisateur Les options Screen Saver, Logout et Inactivity Time permettent de contrôler l'état de la console au cours des périodes d’inactivité. Vous pouvez configurer une déconnexion automatique après expiration d’une certaine période d’inactivité dans le champ Inactivity Time. Vous pouvez également choisir de masquer l'OSD de la console utilisateur avec un économiseur d'écran après une autre période d'inactivité...
Page 189
Le guide d’installation et d’utilisation de la série AMX Modification d’un équipement (en configuration normale) : Appuyez deux fois sur pour lancer l’interface OSCAR. Ctrl Cliquez sur l’onglet Admin. L’écran Device Admin s’affiche. NOTA : L’écran Device Admin affiche uniquement les équipements actuellement sous tension et reliés au système de commutation.
Page 190
Saisissez le nouveau nom que vous souhaitez attribuer à l’équipement dans le champ Name (1 à 15 caractères). Dans la liste déroulante Target, sélectionnez le commutateur KVM Avocent monté en cascade auquel le module IQ est relié. -ou- Sélectionnez KVM Switch si le commutateur monté en cascade n'est pas de la marque Avocent.
Le guide d’installation et d’utilisation de la série AMX Figure 3.28 : Écran Edit Device (configuration en cascade continue) Dans la section MDM Switch, sélectionnez le nombre de voies du commutateur KVM monté en cascade dans la liste déroulante Ports. Dans la section MDM Switch, sélectionnez la séquence de raccourci clavier du commutateur KVM monté...
Chapitre 3 : Opérations Tableau 3.5 : Séquences de raccourci clavier de la ligne de commande de l’OSD Touches de la Description de la séquence séquence Verr num + « - » Maintenez la touche Verr num enfoncée puis appuyez sur la touche Moins (-) Verr num + «...
Le guide d’installation et d’utilisation de la série AMX Saisissez la commande puis appuyez sur pour réinitialiser le clavier. Entrée -ou- Saisissez la commande puis appuyez sur pour réinitialiser la souris. Entrée Désactivation de la connexion automatique utilisateur L’option Auto User Login au niveau de la console utilisateur peut être activée uniquement par l’administrateur mais peut être désactivée par n’importe quel utilisateur.
Chapitre 3 : Opérations Si vous êtes actuellement connecté à l’équipement cible, les valeurs de décalage seront immédiatement appliquées au signal vidéo. Si vous souhaitez enregistrer les paramètres de réglage d’égalisation actuels, cliquez sur Save. Les paramètres de réglage d’égalisation seront mémorisés par la console utilisateur et seront appliqués au signal vidéo lors de chaque connexion à...
ATTENTION :Si vous n’êtes pas sûr de savoir quel tableau DDC correspond à votre système, ne modifiez pas le paramètre du tableau DDC. Contactez votre administrateur système ou le service d’assistance technique d’Avocent pour obtenir de plus amples informations concernant la configuration du tableau DDC. Configuration du tableau DDC : Effectuez la séquence de raccourci clavier par défaut pour afficher la ligne de commande.
Chapitre 3 : Opérations Connexion forcée à un équipement cible À partir de la console utilisateur, vous pouvez forcer la connexion de n’importe quelle console utilisateur du système de commutation à un équipement cible. La console utilisateur hôte envoie des ordres de connexion et de déconnexion forcée. En mode Serial Force, la console utilisateur hôte doit être connectée à...
Le guide d’installation et d’utilisation de la série AMX • [nom du serveur] : nom de l’équipement cible pour lequel vous souhaitez que la console utilisateur force la connexion ou la déconnexion. Le nom du serveur est enregistré dans le module IQ et est affiché dans la liste de l’onglet Target de l’interface OSCAR.
Page 198
Chapitre 3 : Opérations Ces paramètres ne peuvent pas être modifiés. Les paramètres de configuration série de l’équipement série relié à la console utilisateur hôte doivent concorder. Désactivation du mode Serial Force : Décochez la case Serial Force Mode parmi les paramètres de verrouillage de la console utilisateur. Reportez-vous à...
AMWorks. Pour plus d’informations sur l'ajout forcé d’un commutateur externe au commutateur AMX, référez-vous au fichier MIB spécifique intitulé AMX-MIB. Ce fichier MIB est disponible sur le CD du logiciel AMWorks. Vous pouvez également télécharger le fichier AMX-MIB depuis l’adresse Internet www.avocent.com/support en cliquant sur l’option Product Upgrades.
CHAPITRE Utilisation de la voie terminal Accès au menu Terminal Vous pouvez configurer un commutateur AMX depuis l’unité en passant par la voie du terminal. Toutes les commandes du terminal sont accessibles à partir d’un terminal ou d’un PC exécutant un logiciel d’émulation de terminal.
Veillez à ne pas l’oublier ni l’égarer. Ce mot de passe ne peut pas être réinitialisé ou retrouvé s’il est perdu ou oublié. En cas de perte de votre mot de passe, contactez le service d’assistance technique d’Avocent.
Page 202
Chapitre 4 : Utilisation de la voie terminal SNMP Configuration L’option de configuration SNMP du menu Terminal Applications vous permet de configurer les paramètres suivants du protocole SNMP : • Activation et désactivation SNMP • Définition des noms de communauté des champs de lecture, d’écriture et d’interruption •...
Le guide d’installation et d’utilisation de la série AMX Gestion SNMP d’objets de commutation AMX Le protocole SNMP vous permet de contrôler et de gérer des objets de la base de données MIB (Management Information Base) spécifiques aux commutateurs AMX. Reportez-vous au Tableau 4.2 pour obtenir une description des groupes d’objets MIB du système AMX.
A NNEXES Annexes Annexe A : Spécifications techniques Tableau 1.1 : Spécifications techniques du commutateur AMX5000 Voies serveur Nombre Connecteurs Connecteur RJ-45 pour commutateur AMX Voies utilisateur Nombre Connecteurs Connecteur RJ-45 pour commutateur AMX Connexion réseau Nombre Type Ethernet, 10BaseT, 100BaseT Connecteur RJ-45 Voie de terminal...
Le guide d’installation et d’utilisation de la série AMX Tableau 1.1 : Spécifications techniques du commutateur AMX5000 (suite) Certifications et labels de sécurité UL, FCC, cUL, ICES-003, CE, VCCI, C-Tick et EMC Tableau 1.2 : Spécifications techniques du commutateur AMX5010 Voies serveur Nombre Connecteurs...
Le guide d’installation et d’utilisation de la série AMX Tableau 1.3 : Spécifications techniques du commutateur AMX5020 (suite) Fonctionnement : 0 à 50 °C Températures Hors fonctionnement : -20 à 60 °C Humidité Fonctionnement : 10 à 90 % sans condensation Certifications et labels de sécurité...
Annexes Tableau 1.4 : Spécifications techniques du commutateur AMX5030 (suite) Alimentation c.a. 100 à 240 V c.a., 50 à 60 Hz Fonctionnement : 0 à 50 °C Températures Hors fonctionnement : -20 à 50 °C Humidité Fonctionnement : 10 à 90 % sans condensation Certifications et labels de sécurité...
Le guide d’installation et d’utilisation de la série AMX Tableau 1.5 : Spécifications techniques de la console utilisateur AMX5130 (suite) Matériel compatible Claviers et souris PS/2 et USB, haut-parleurs, microphone, équipements série (débit Périphériques en bauds maximum de 38 400 bauds) 1 280 x 1 024 avec 300 mètres de câble UTP de l’équipement cible à...
Annexes Tableau 1.6 : Spécifications techniques des consoles utilisateur AMX5111 et AMX5121 (suite) Matériel compatible Périphériques Clavier et souris PS/2, clavier et souris USB 1 024 x 768 (console utilisateur ) ou 1 280 x 1 024 (console utilisateur ) avec 300 Résolution vidéo mètres de câble UTP de l’équipement cible à...
Le guide d’installation et d’utilisation de la série AMX Tableau 1.7 : Spécifications techniques du module AMIQ (suite) Poids 0,13 kg Environnement Consommation 650 mW d’énergie Tension nominale 5 V c.c. d’alimentation (c.c.) Fonctionnement : 10 à 50 °C Températures Hors fonctionnement : -20 à...
Annexes Tableau 1.8 : Spécifications techniques du module AMIQDM (suite) Données mécaniques H x l x P 20 x 39 x 78 mm Poids 0,13 kg Environnement Consommation d’énergie Tension nominale 5 V c.c. d’alimentation (c.c.) Fonctionnement : 0 à 40 °C Températures Hors fonctionnement : -20 à...
Page 213
Le guide d’installation et d’utilisation de la série AMX Tableau 1.9 : Spécifications techniques du module AMIQ-SRL (suite) Données mécaniques H x l x P 20 x 39 x 78 mm Poids 0,13 kg Environnement Intensité nominale 230 mA d’alimentation (c.a.) Tension nominale 5 V c.c.
Annexes Annexe B : Utilisation des modules AMIQ-SRL Le module AMIQ-SRL est un convertisseur série/VGA permettant aux équipements compatibles avec VT100 d’être visualisés par la console utilisateur AMX51xx. Les données série proprement dites ne sont pas disponibles mais uniquement visibles. Toutes les données série provenant de l’équipement cible sont affichées dans une fenêtre VT100, placées dans un tampon vidéo puis envoyées à...
Page 215
Le guide d’installation et d’utilisation de la série AMX • Enter Sends : permet de définir les touches à transmettre lorsque vous appuyez sur Entrée Les options disponibles sont <CR> (Entrée) ou <CR><LF> (Entrée Saut de ligne). • Received : permet de définir la manière dont le module interprète un caractère reçu.
Page 216
Annexes • Break Key Sequence : permet de définir la combinaison de touches générant une condition d’interruption. La combinaison de touches par défaut est Alt+B Configuration d’un module AMIQ-SRL Appuyez sur . L’écran de configuration s’affiche. Ctrl+F8 Sélectionnez le paramètre à modifier. Vous pouvez parcourir l’écran de configuration à l’aide des touches fléchées Haut Modifiez la valeur sélectionnée à...
Le guide d’installation et d’utilisation de la série AMX Utilisation du mode History Le mode History vous permet d’examiner le tampon de l’historique qui contient les événements survenus. Le module AMIQ-SRL dispose d’un tampon de sortie de 240 lignes au minimum (équivalant à 10 écrans).
Annexes Brochage du module AMIQ-SRL Le tableau suivant dresse la liste des broches du module AMIQ-SRL. Tableau 1.11 : Broches du module AMIQ-SRL Signal hôte DB9-F Circulation du signal Nom/description du signal SRL Nom/description DCD - Détection de Hors du SRL DTR - Terminal de données prêt porteuse RXD - Réception de...
Le guide d’installation et d’utilisation de la série AMX Annexe C : Paramètres de configuration de l’écran Edit Device de l’interface OSCAR Tableau 1.12 : Commutateur KVM AutoView Paramètres de configuration de l’écran Edit Device Équipement cible Commutateur AutoView Voies 4, 8 Raccourci clavier Verr num + «...
Annexes Tableau 1.15 : Commutateur AV2000R, AV1000R, AV2000 ou DSR (suite) Commutateurs AV2000R, AV1000R, AV2000 : 16 Voies Commutateurs DSR : 8, 16 La touche Impr écran ne fonctionne pas pour une connexion Raccourcis clavier d’équipement cible. Configuration requise : il est recommandé de sélectionner l’ordre Configuration de l’unité...
Page 221
Le guide d’installation et d’utilisation de la série AMX Tableau 1.18 : IBM C2T (suite) Raccourci clavier Verr Num - Verr Num Tableau 1.19 : Commutateur KVM Paramètres de configuration de l’écran Edit Device Équipement cible Commutateur KVM Voies 1, 2, 4, 8, 12, 16, 20, 24, 28, 32 Ctrl-Ctrl (G), Ctrl-Ctrl (D), Ctrl-Ctrl (G-D) Alt-Alt (G), Alt-Alt (D), Alt-Alt (G-D) Maj-Maj (G), Maj-Maj (D), Maj-Maj (G-D)
Si une mise à jour est nécessaire, rendez-vous sur le site www.avocent.com pour télécharger la version du firmware la plus récente. Effectuez une mise à jour Flash de votre système de commutation AMX avec la nouvelle version du firmware grâce à...
Page 223
Le guide d’installation et d’utilisation de la série AMX Configuration La Figure 1.1 illustre un système de commutation AMX configuré pour le mode de commutation clavier-souris. La console utilisateur à deux voies est reliée au commutateur AMX, ce qui lui permet d'accéder aux équipements cibles distants ainsi qu'à un équipement cible local.
Page 224
Annexes Activation du mode de commutation clavier-souris Activez ou désactivez le mode de commutation clavier-souris à l'aide de la ligne de commande de l'OSD. Le Tableau 1.20 dresse la liste des commandes qui concernent le mode de commutation clavier-souris et qui peuvent être saisies dans la ligne de commande. Tableau 1.20 : Commandes du mode de commutation clavier-souris Commande Résultat...
Page 225
Le guide d’installation et d’utilisation de la série AMX Saisissez le raccourci de commutation clavier-souris, . Vous pouvez alors contrôler l'équipement cible local avec le clavier et la souris. Pour commuter de nouveau vers l'équipement cible distant, il vous suffit de saisir NOTA : Si la console utilisateur est configurée pour afficher l'indicateur de l'équipement cible, l'indicateur de l'équipement cible local affiche «...
Annexes Annexe E : Dépannage Une ou deux couleurs ne s’affichent pas au niveau du serveur ou de la console utilisateur • Vérifiez la connexion VGA entre la console utilisateur et le moniteur. • Vérifiez la connexion VGA entre le module IQ et le serveur. •...
Page 227
Le guide d’installation et d’utilisation de la série AMX vous qu’aucun commutateur n’a une voie utilisateur connectée à l’arrière d’une de ses voies serveur. Reportez-vous à la section Installation d’un système de commutation AMX monté en cascade à la page 22 pour de plus amples informations. •...
Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une difficulté, suivez les procédures ci-dessous afin de bénéficier d’une aide le plus rapidement possible.
Page 229
Le guide d’installation et d’utilisation de la série AMX...
Compensation des mouvements vidéo 2 Assistance technique 99 Configuration en cascade 22, 25 Auto User Login 58 commutateurs d’une autre marque qu’Avocent 25 configurations bloquantes et non- Câbles UTP 4, 6 bloquantes 22, 25 Chemins utilisateur 22, 24 continue 3 Choix de l’emplacement 41...
Page 231
Le guide d’installation et d’utilisation de la série AMX connexion forcée 67, 70 onglet User 34 console utilisateur cible 67 paramètres administrateur 54 console utilisateur hôte 67 paramètres utilisateur 54 définition 4 Émulation des données série émulation des données audio et série 53 à...
Page 232
26, 27 Module IQ 1 mise à jour Flash 30 à propos de 6 avec commutateurs KVM montés en cascade d’une autre marque qu’Avocent 25 configuration MDM 35 voir Multiple Device Mode 22 définition 4 Menu Terminal Applications informations relatives à la version 55 accès 71...
Page 233
Le guide d’installation et d’utilisation de la série AMX à propos de 6 menu Terminal Applications 72 configuration 10 modification du mot de passe 44 configuration clavier 61 modification du mot de passe utilisateur 47 spécifications techniques 81 Multiple Device Mode 22, 35 Voyants 31 configuration 25, 62 module AMIQDM...
Page 234
Index consoles utilisateur AMX5111 et AMX5121 81 environnements de diffusion 28 Routeur nVision gestion du système 72 à propos de 2 identifiant de configuration 15, 72 configuration depuis le logiciel AMWorks 29 ligne de commande de l’OSD 62 utilisation avec un système de mise à...