Troubleshooting - Vacmaster VJC809PF Operator's Manual

Table of Contents

Advertisement

WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE

TROUBLESHOOTING

Symptom
Vacuum will not operate
Dust comes from motor cover.
Reduced efficiency and motor/
speed vibration.
TROUBLESHOOTING
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Collection tank full.
1) The dust fi lter is missing or
damaged.
2) Vacuum has been used
to collect fi ne dust, such as
drywall dust, fi replace soot,
or ash, without a fi ne dust
fi lter equipped.
1) There is a blockage in the
nozzle or hose, or the
collection tank inlet. Or dust
fi lter blocked by fi ne dust.
Corrective Action
1) Check power supply – cord,
2) Unplug and check the
3) Empty collection tank.
1) Attach or replace dust fi lter.
2) Remove the standard
1) Check nozzle, hose and
12
breakers, fuses.
power cord. If damaged,
have it repaired by a
professional.
cartridge fi lter and install the
appropriate fi ne dust
cartridge fi lter.
collection tank inlets for
blockage. Take off the fi lter
and clean it. Or install new
dust fi lter.