Panasonic KX-TG4763B Service Manual page 65

Hide thumbs Also See for KX-TG4763B:
Table of Contents

Advertisement

12.7.1.2. Handset
First, operate the PC setting according to The Setting Method of JIG (P.56).
Then download the appropriate data according to the following procedures.
EEPROM (IC3)
X'tal (X1)
Note:
(*2) XXX_YYY: revision number
"XXX" and "YYY" vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (P.56).
12.7.1.3. Range Extender
First, operate the PC setting according to The Setting Method of JIG (P.56).
Then download the appropriate data according to the following procedures.
EEPROM (IC611)
X'tal (X501)
Note:
(*3) XXX: country code, YYY: revision number.
"XXX" and "YYY" vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (P.56).
Downloaded from
www.Manualslib.com
Items
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
System clock
Items
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
System clock
manuals search engine
How to download/Required adjustment
1) Default batch file: Execute the command "default.bat".
2) Default batch file (remaining): Execute the command
"TGA470US_DEF_RevXXX_YYY.bat". (*2)
3) Country version batch file: Execute the command
"TGA470US_US_RevXXX_YYY.bat". (*2)
4) Clock adjustment
5) 2.35 V setting and battery low detection
1) Apply 2.6V between BATT+ and BATT- with DC power.
2) Input Command "sendchar sfr", then you can confirm the
current value.
3) Check X'tal Frequency.(13.824 MHz ± 100 Hz).
4) If the frequency is not 13.824 MHz ± 100 Hz, adjust the
frequency of CLK executing the command "sendchar sfr xx xx
(where xx is the value)" so that the reading of the frequency
counter is 13.824000 MHz ± 5 Hz.
How to download/Required adjustment
1) Change the address "0000" of EEPROM to "22" to download
the data.
2)
Default
batch
file:
"TGA405USUSrevXXX_YYY.bat. (*3)".
3) Clock adjustment
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Apply 6.5V between DCP ad DCM with DC power.
2) Input Command "sendchar sfr", then you can confirm the cur-
rent value.
3) Check X'tal Frequency.(13.824 MHz ± 100 Hz).
4) If the frequency is not 13.824 MHz ± 100 Hz, adjust the fre-
quency of CLK executing the command "sendchar sfr xx xx
(where xx is the value)" so that the reading of the frequency
counter is 13.824000 MHz ± 15 Hz.
65
KX-TG4763B/KX-TGA470B/KX-TGA405B
Execute
the
command

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tga470bKx-tga405b

Table of Contents