Download Print this page

OPTI-UPS Clever Series CS385B Specification Sheet

Opti-ups ups specification sheet

Advertisement

Quick Links

For stylish home and office
CS385 / CS530B / CS730B / CS500B
CS385B / CS530B / CS730B
* Fully digitized microprocessor control
* Energy saving (UPS sleep mode )
* 50/60Hz frequency auto sensing
* Buzzer can be muted by pressing "ON/OFF" button
* Single PCB with reliable design
* Clear LED alarms
* Cold start (DC power on)

Rear Panel

CS385B
Breaker
Battery
Backup
Bypass
CS530B / CS730B
Breaker
Bypass
Battery
Backup
* Short circuit and overload protection
* Advanced battery management (ABM)
* Automatic diagnostics & battery check
* Surge protection of all outlets
* EMI/RFI noise filter
Model Name
OUTPUT
UPS Capacity
No. of Sockets
Voltage
(on battery*)
Frequency (on battery)
Transfer Time
INPUT
Voltage
(single phase)
Frequency
PROTECTION
Unit Input
Overload Protection
Short Circuit
Spike Protection
BATTERY
Type
Typical Recharge Time
(to 90% of full capacity)
Back-up Time
PC with
8 - 12 minutes
15" LCD
Protection
PHYSICAL
Net Weight kg (lbs)
1.6 (3.52)
95 x 95 x 158 mm
Dimension WxDxH
INTERFACE
Sends battery low & power failure signals, and receives shutdown signal from computer
Dry Contact (option)
Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status
USB (option)
ALARM
Battery Backup
Battery Low
UPS Works at Full Load
Overload
ENVIRONMENT
Ambient Operation
Audible Noise
* See VS1000C on page 6
3.
* CS385B / CS530B / CS730B
CS 385B
CS 530B
385VA
530VA
NEMA 5-15R
UPS x 2, Bypass x 2
Simulated sine wave at
100V / 115V / 220V / 240V < +/- 5% AVR controlled by PWM
50 or 60Hz +/- 0.3 Hz
< 10 milliseconds, including detection time
100V +/- 20%, 110V +/- 25%
220V / 230V / 240V, 170V~280 at line input
50 or 60 Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS Automatic shutdown if overload exceeds 105% of
nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds
UPS output cut off immediately
460 joules, 2ms
Sealed, maintenance-free lead acid batteries with 3-5 years
typical life time
6 hours
Automatic self- test, Over discharge protection, short circuit
protection by fuse
2.6 (5.72)
Short beeping sound every 4 seconds
(Buzzer can be muted by pressing main switch button)
Rapid beeping sound every seconds
Long continuous beeping sound every 4 second
Continuous beeping sound
3,500 meters max elevation, 0-95% humidity
(No-condensing water),0-40 deg C
<40dBA (1 meter form surface)
NEMA 5-15 Only
Thailand,
CS 730B
730VA
15 - 18 minutes
2.6 (5.72)
95 x 138 x 158 mm