Example Timing Diagrams Of Advanced Synchronization Control - Schäfter+Kirchhoff SK7500GTO-XL Instruction Manual

Monochrome line scan camera
Table of Contents

Advertisement

4 Advanced SkLineScan Software Functions

Example Timing Diagrams of Advanced Synchronization Control

Annotations:
SyncA
= LINE SYNC A
SyncB
= LINE SYNC B
Count
= internal counter
Trigger
= Generated trigger pulses from the Trigger Control stage. The signal goes to the Trigger
Divider stage inside the camera. For setting the divider use the Vyyyyy<CR> command or the
'Divider' input field in the 4.1 Camera Control by Commands, p. 20.
1) direction changed
2) glitch
• Trigger on falling edge
A
of SyncA
• SyncB without function
• direction detection = off
• hysteresis = 0
Sync Control Register:
'00000xxx'b
B
• Trigger on falling edge
of SyncA
• SyncB = low active
• direction detection = on
• hysteresis = 0
Sync Control Register:
'10000xxx'b
• Trigger on falling edge
C
of SyncA
• SyncB = low/high active
• direction detection = on
• hysteresis = 0
Sync Control Register:
'11000xxx'b
• Trigger on 4 edges
D
of SyncA and SyncB
• direction detection = on
• hysteresis = 0
Sync Control Register:
'11100xxx'b
• Trigger on 4 edges
E
of SyncA and SyncB
• direction detection = on
• hysteresis = 4
Sync Control Register:
'11101xxx'b
© 2015
Schäfter + Kirchhoff GmbH • Hamburg
(external line synchronization input, I/O connector)
(external line synchronization input, I/O connector)
SK7500GTO-XL Instruction Manual (11.2015)
1)
1)
1)
1)
1)
machine holdup oscillation
1)
1)
2)
23