Servicing The Fuses; Servicing The Battery; Installing The Battery - Toro 74236 Operator's Manual

With 62" sfs side discharge mower
Table of Contents

Advertisement

Servicing the Fuses

The electrical system is protected by fuses. It requires no
maintenance, however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse: Main –20 amp, blade-type
Alternator –30 amp, blade-type
Fan–30 amp, blade-type
1. To gain access to the main fuse, raise the seat. To gain
access to the fan and alternator fuses, raise the seat and
tilt the engine cover forward.
2. To replace a fuse, pull out on the fuse to remove it
(Fig. 65).
2
Figure 65
1. Fan—30 amp.

Servicing the Battery

Warning
Battery posts, terminals, and related accessories
contain lead and lead compounds, chemicals
known to the State of California to cause cancer
and reproductive harm. Wash hands after
handling.
Checking Electrolyte Level
1. With the engine off, open the hood to locate the battery.
2. Look at the side of the battery. The electrolyte must be
up to the upper line (Fig. 66). Do not allow the
electrolyte to get below the lower line (Fig. 66).
1
m–3653
2. Main—20 amp.
45
3. If the electrolyte is low, add the required amount of
distilled water; refer to Adding Water to the Battery,
page 46.
1
2
3
Figure 66
1. Filler caps
2. Upper line
Danger
Battery electrolyte contains sulfuric acid which is a
deadly poison and causes severe burns.
Do not drink electrolyte and avoid contact with
skin, eyes or clothing. Wear safety glasses to
shield your eyes and robber gloves to protect
your hands.
Fill the battery where clean water is always
available for flushing the skin.
Follow all instructions and comply with all
safety messages on the electrolyte container.

Installing the Battery

1. Position battery in tray with terminal posts toward the
engine (Fig. 67).
2. First, install the positive (red) battery cable to positive
(+) battery terminal.
3. Then install negative battery cable and ground wire to
the negative (–) battery terminal.
4. Secure cables with 2 bolts (1/4 x 3/4 in.), 2 washers (1/4
in.), and 2 locknuts (1/4 in.) (Fig. 67).
5. Slide the red terminal boot onto the positive (red)
battery post.
m–5004
3. Lower line