TROUBLESHOOTING

If the pump is not running properly, remove the 6 impeller cover screws (#1), remove the impeller
cover (#2), and inspect the O-ring (#3) and impeller (#4). If there are any damages to these parts,
please contact 1-800-346-7611.
Note: Do not disassemble the motor housing of the pump. This pump has NO repairable
internal parts, and disassembling may cause a dangerous electrical wiring conditions.
2
1
4
3
Item
1
2
3
4
5
6
7
5
Description
Qty
Screw
Impeller cover
O-ring
Impeller
Shaft
Washer
Hose connection
7
6
4
1
1
1
1
1
1
7