Maintenance - red lion RL-SWJ Series Owner's Manual

Shallow well jet pump
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE

s
WARNING
RISK OF ELECTRICAL SHOCK
!
Before servicing motor-operated equipment, shut off the power at the main electrical panel and disconnect the power supply from motor and accessories.
Use safe working practices during servicing of equipment.
PERFORM INSPECTIONS MONTHLY
1. Ensure pump is still securely bolted to the foundation.
2. To avoid any fire hazards, ensure that there is adequate clearance
from any combustible materials, shelving or cabinets. Ensure
there are no leaves or debris near the pump.
3. Ensure that the motor is securely wired into a proper GFCI-
protected circuit. Test the GFCI periodically by pressing the test
switch when the pump is operating. This should shut off the
pump. If the GFCI does not shut the pump off, have an electrician
replace the GFCI as soon as possible. Remember to reset the GFCI
by pressing the reset switch.
4. Look for any signs of leaks in pipes. Replace or repair, if necessary.
5. Clean the exterior of the pump, if needed, with a solution of
vinegar and water.
DRAINING
Should the unit be subject to freezing, it will be necessary to drain the
pump and tank. To do this, shut off the power to the pump at the main
electrical panel. Open a tap in the water system to release the pressure.
Remove the drain and priming plugs from the pump casing. Remove the
pressure tank drain plug (if so equipped). Allow ample time for the system
to drain before reinstalling the plugs.
LUBRICATION
The pump requires none.
REPLACING MECHANICAL SEAL
s
CAUTION
!
MAINTENANCE ON ELECTRICAL AND/OR MECHANICAL DEVICES.
Disassembly:
1.
Shut off the power to the pump at the main service panel and
disconnect the power supply from motor.
2. Open a tap in the water system to release the pressure.
3. Remove the drain and fill plugs to allow the pump to drain.
4. Remove the bolts (1) and remove casing (2).
5. Remove fan shroud fasteners from the motor and remove the
fan shroud (3).
s
CAUTION
!
the motor fan or shroud.
6. Remove the impeller (4) by firmly holding on to the motor fan
(5) and turn the impeller in a clockwise direction.
7.
Slip rotating seal (9) off the shaft.
8. Remove motor tie bolts and remove motor (6) from adapter (7)
by slightly tapping end of motor shaft with a mallet.
9. Remove the adapter plate and the O-ring.
Reassembly:
1.
Clean all parts thoroughly before assembling.
2. Lightly lubricate (soapy water) the rubber cap on the ceramic
seal (8) and push it into the adapter (7) using thumbs only. Make
sure the smooth surface of the ceramic seat faces outward.
s
CAUTION
!
cleaners or lubricants.
s
CAUTION
!
contaminate the ceramic seal face.
NOTE: If the pump will remain out of service for longer
than one week, the seal components must be installed dry
(no lubrication).
3. Reassemble the motor (6) to the adapter. Align the tabs of the
adapter plate with the slot at the bottom of the motor housing.
13
(See Figure 8)
ONLY DULY QUALIFIED PERSONS SHOULD PERFORM
Care must be taken not to damage
Do not use petroleum-based
Care must be taken not to

Advertisement

Table of Contents
loading

Table of Contents