2-3. Other Component Specifications

Indoor Unit
SAP – K92AH
SAP – K122AH
Transformer (TR)
Rating
Coil resistance
Thermal cut-off temp.
Thermistor (Coil sensor)
Resistance
Thermistor (Room sensor)
Resistance
Outdoor Unit
SAP – C92AH
4-way Valve (20S)
Coil rating
Coil resistance
Outdoor Unit
SAP – C122AH
Thermostat (Fan Speed Control 23S)
Switching temp.
Contact rating
Power Relay (for outdoor fan motor)
Coil rating
Contact rating
This power relay is provided to protect the outdoor fan to operate in Low fan speed during heating mode.
NOTE
In heating operation, the outdoor fan should always run in High fan speed to prevent the unit from freezing.
4-way Valve (20S)
Coil rating
Coil resistance
PTC Thermistor (TH)
Rating
Primary
Secondary
Capacity
(at 25°C)
kΩ
kΩ
(at 20°C)
°C
(at 20°C)
AC 230V, 50 / 60 Hz
Primary (WHT – WHT):
Secondary (BRN – BRN):
DTN-TKS131B
0°C
DTN-TKS128B
25°C
LB81012 (Coil), VK1100B (Valve)
AC 220/240V, 50/60Hz, 6W
high
low
HH62S AC220/240V
LB81012 (Coil), VK1100B (Valve)
AC 220/240V, 50/60Hz, 6W
ZPROYCE101A500
8
ATR-I55
13.7V, 0.4A
5.48VA
307 ± 10%
1.8 ± 10%
150°C
15.0 ± 2%
5.0 ± 3%
3,030 ± 7%
MQT5S
28.5°C ± 1.5
LOW
31.5°C ± 2
HIGH
AC 220V, 3A
AC 220/240V
AC 250V, 10A
3,030 ± 7%
400V, 115A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap – c92ahSap – k122ahSap – c122ah

Table of Contents