4. REFRIGERANT FLOW DIAGRAM

Indoor Unit
SAP – K92AH
Indoor unit
Indoor Unit
SAP – K122AH
Indoor unit
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the wide and
narrow tubes of this air conditioner become cold. To prevent heat loss
and wet floors due to dripping of condensation, both tubes must be
well insulated with a proper insulation material. The thickness of the
insulation should be a min. 8 mm.
CAUTION
Wide tube
O.D.
ø9.52 mm
(3/8 ")
Narrow tube
O.D.
ø6.35 mm
(1/4")
Wide tube
O.D.
ø12.7 mm
(1/2 ")
Narrow tube
O.D.
ø6.35 mm
(1/4")
After a tube has been insulated, never try to
bend it into a narrow curve because it can
cause the tube to break or crack.
Outdoor Unit
Outdoor unit
Wide tube
service
valve
Muffler
Narrow
tube
Capillary tube
service
(for heating)
valve
Strainer
Check
valve
Outdoor Unit
Outdoor unit
Wide tube
service
valve
Muffler
Narrow
tube
(both for heating and cooling)
service
valve
Muffler
11
SAP – C92AH
Accumulator
4-way
valve
Capillary tubes
(both for heating
and cooling)
SAP – C122AH
Accumulator
4-way
valve
Capillary tubes
Strainer
Insulation
Thickness:
Min. 8 mm
Wide tube
Cooling cycle
Heating cycle
Cooling cycle
Heating cycle
Thickness:
Min. 8 mm
Narrow tube