C. Hub Ring Out (RJ45) to distant hub Ring In (RJ45)
Application C shows the Ring Out of one hub connected to the Ring In of
another hub via a pair of OmniHawk™ converters. Note that the cable from
the second OmniHawk™ to the Ring In is a crossed cable.
D. Distant Lobe Extension
Application D shows a distant hub in lobe extension via a pair of OmniHawk™
converters. In this configuration a standard CAT-5 cable connects the ex-
tended hub to the first OmniHawk™, fiber optic cables connect the two
converters, and another standard CAT-5 patch cable connects the second
OmniHawk™ to the target hub.
E. Other Applications
The above examples show the most common applications of the
OmniHawk™. Your network may require an application not listed here. The
configuration you need will be supported by the OmniHawk™ as long as
the correct cable is used. The fiber optic cables will always be the same.
The table below will guide you in selecting the proper copper cables, media
filters, and connector adapters.
OST PART #
CONNECT FROM
9300-P45
OmniHawk™ RJ45
OmniHawk™ RJ45
9301-P45X
OmniHawk™ RJ45
OmniHawk™ RJ45
5700-CMF &
OmniHawk™ RJ45
9301-P45X
5701-IP45 &
OmniHawk™ RJ45
9300-P45
OmniHawk™ RJ45
5701-IP45 &
OmniHawk™ RJ45
9301-P45X
9310-IF9
OmniHawk™ DB9
9311-IF9X
OmniHawk™ DB9
OmniHawk™ DB9
9320-FM9
OmniHawk™ DB9
CONNECT TO
Lobe, RJ45
Ring Out, RJ45
Ring In, RJ45
Workstation, RJ45
Workstation, DB9(if not directly
attaching the OmniHawk™ to the
workstation)
Lobe, IBM Data Connector
Ring Out, IBM Data Connector
Ring In, IBM Data Connector
Ring In, IBM Data Connector
Ring Out, IBM Data Connector
Lobe, IBM Data Connector
Workstation, DB9(if not directly
attaching the OmniHawk™ to the
workstation)
10
The bottom left LED is yellow / red, the remaining three LEDs are yellow /
green. The meaning of the LEDs are shown on the cover of the OmniHawk™
and in the tables below.
POWER UP LED TEST
ALL LEDS
Yellow for 1/2 second then Green or Red
or 1/2 second
Any other behavior
The OmniHawk™ performs a self test every time power is newly applied.

OPERATIONAL MODES

FIBER READY
MEANING
(top left)
Data received from
GREEN
fiber
No data is being
Off
received from Fiber
POWER /
ERROR (bot.
MEANING
left)
YELLOW
Power is on
An attachment error
RED
occurred
MEANING
Self Test OK
Failed Self Test, Call Technical Support
COPPER READY
MEANING
(top right)
Data received from
GREEN
copper
No data is being
OFF
received from copper
INSERT STATUS
MEANING
(bot. right)
The fiber optic and
GREEN
copper interfaces have
both actively inserted
FLASHING
Still attempting to
GREEN
insert
Insertion is not being
OFF
attempted
3