Technical Specifications - Omnitron Systems Technology 4/16 Token Ring Fiber Converter OmniHawk User Manual

Token ring fiber converter
Table of Contents

Advertisement

CONNECTORS, SWITCHES & INDICATORS
CONNECTORS
The OmniHawk™ has three interface connectors: a fiber optic transmitter
and receiver pair, an RJ45 jack, and a DB9 male connector.
The DB9 connector and the chassis are designed to attach directly to the
rear of a workstation network interface card. The jack screws ensure a solid
connection.
The RJ45 connector is designed to attach directly to a hub lobe or ring out
via a CAT-5 patch cable. The RJ45 connector may attach to a ring in with a
crossed patch cable (transmit and receive pairs crossed).
Note that only one copper interface may be used at a time. Other connec-
tions are possible with special cables. Omnitron's technical support depart-
ment can assist you with your special needs.
SWITCHES
The OmniHawk™ has two switches which control the attachment mode.
The switches are located to the right of the DB9 connector.
Both switches are placed in the UP position at the factory. The following
table explains the switch settings.
ATTACHMENT MODE
Automatic Sensing
UTP/STP --> RO or Station
UTP/STP --> RI or Lobe
Self Test / Media Test
CONNECTORS
In addition to the two switches there are four LED indicators in a 2 x 2
cluster. Refer to the drawing below.
SWITCH 1
SWITCH 2
Up
Up
Up
Down
Down
Up
Down
Down
2

TECHNICAL SPECIFICATIONS

Protocol:
Token Ring (IEEE 802.5)
Cables
Fiber Optic:
Multi-mode glass fiber of sizes 50/125,
62.5/125, or 100/140 micron
STP:
DB9 female
UTP:
CAT-5 (EIA/TIA 568):
(lower grade wiring at shorter distances)
Data Rate:
16 Mbps or 4 Mbps
Supported Distances
Fiber Optic:
2.5 Km multi-mode
20 Km single-mode
UTP:
300 m
Indicators
FO Ready
Yellow - Green LED
Cu Ready
Yellow - Green LED
Power/Error
Yellow - Red LED
Insert Status
Yellow - Green LED
Dimensions:
W: 3.46" x D: 2.83" x H: 0.78"
Power:
External Power Supply 9 VDC @ 1.2A
Temperature
Operating:
0 to 45 degrees C
Storage:
-40 to 75 degrees C
Humidity:
Up to 90% (non condensing)
11