Install Linkage Rod
1. Insert front end of linkage rod through hole in handle
assembly while hooking rear end of linkage rod thru
hole in rear tab on deflector assembly (Fig. 8).
Note: When mounting a debris blower on a traction unit
equipped with a cab, rotate handle 180_ and use front tab
on deflector for rod installation.
2. Secure each end of rod with a flatwasher and cotter pin.
Figure 8
1. Linkage rod
2. Handle assembly
Replace PTO Manifold Orifice
Note: On traction units that have a gold colored PTO
manifold (Fig. 9) orifice must be removed and replaced. If
PTO manifold is silver, orifice does not need to be
replaced.
1. Using a 1/8" Allen wrench, remove orifice plug from
MR port of front PTO manifold (Fig. 9).
2. Order plug Part No. 3246–17 from your Toro distributor
and install into MR port of manifold with a 5/32" Allen
wrench.
2
1
3
3. Rear tab
10
1
2
Figure 9
1. Manifold block
Mount Blower To Traction Unit
1. Move traction unit up to blower until lift arms are
aligned with blower arm assemblies (Fig. 10).
3
1
Figure 10
1. Lift arm ball joint mount
2. Arm assembly
2. Orifice
2
4
3. Clamping plate
4. Reinforcing plate