MSI/Plessey Settings:
Enable/Disable MSI/Plessey
If enabled, MSI/Plessey symbology will be read, subject to the reading
restrictions specified by this set of options. If disabled, the data from the sym-
bology will be disregarded.
SELECTION CODE: F7
MSI/Plessey Enable
MSI/Plessey Disable
Check Digit
The MSI/Plessey symbology requires a check digit, and can optionally have
two check digits. The reader can either send the check digit(s) as part of the
data, or strip it before transmission to the host.
SELECTION CODE: F7
Send Check Digit
Do Not Send Check Digit
Select only one of the following check digit schemes:
SELECTION CODE: F7
One Mod 10 Check Digit
Two Mod 10 Check Digits
Mod 10/Mod 11 Check Digits
Telepen Setting:
Enable/Disable Telepen
If enabled, Telepen symbology will be read, subject to the reading restrictions
specified by this set of options. If disabled, the data from the symbology will
be disregarded.
SELECTION CODE: F8
Telepen Enable
Telepen Disable
Numeric / ASCII Mode
If set to Numeric Mode, each original Telepen code will be translated into
2-digit numeric pair. Otherwise, ASCII or Numeric data will be sent out
accor-ding to the AIM specification.
SELECTION CODE: F8
Numeric Mode
ASCII Mode
A
B
C
D
E
F
G
A
B
C
D
21