Inhalation Method (Using Optional Accessories) - Omron NE-U780 Instruction Manual

Ultrasonic nebulizer
Table of Contents

Advertisement

Inhalation Method (using optional accessories)

Using a bacterial filter
You can use the optional U17-2-E Bacterial Filter to generate air from which bacteria has been removed.
The filter cannot be reused and should be discarded after use.
The following optional accessories are required in order to use the U17-2-E Bacterial Filter:
Long time Nebulization set NEB-LMCC-78E
Fan cover for bacterial filter NEB-BFC-78E
An additional inhalation hose M NEB-HS-L70E
Note: Required in addition to parts used for inhalation.
Using the optional NEB-LMCC-78E Long time Nebulization set instead of the medication cup cover,
assemble the removable water tank and nebulization set just as during normal inhalation. See steps
2
in the "Before Inhalation" section. (
Attach the fan cover for
1
bacterial filter.
Instead of the normal fan cover, use the
optional NEB-BFC-78E Fan Cover for
Bacterial Filter.
Remove the air volume
2
adjustment lever on the long
time nebulization set and close
the air outlet with the air outlet
cap.
Secure the removable water
3
tank to which you have attached
the long time nebulization set to
the main unit.
Long time
Nebulization set
(NEB-LMCC-78E)
3
13
Page 7)
Air volume
adjustment lever
2
Air outlet cap
Fan cover for
bacterial filter
Air
(NEB-BFC-78E)
outlet
1
Remove the bacterial filter cap
4
from the long time nebulization
set.
Attach the bacterial filter to the
5
long time nebulization set.
Attach the inhalation hose to
6
the bacterial filter and connect
the other end of the hose to
the fan cover's air outlet.
Inhalation hose
6
Bacterial Filter
(U17-2-E)
5
4
Bacterial
filter cap
For subsequent steps, see No. 2 under Step
the "Before Inhalation" section. (
Set the air-flow volume to "10" when using the
bacterial filter.
1
and
in
3
Page 9)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents