Omega Engineering OMB-NETSCAN 1500 User Manual page 61

Ethernet/internet-based data logging & control instrument
Table of Contents

Advertisement

Device
...
Interface
Setup IEEE 488
The IEEE 488 Setup dialog box appears. Valid addresses are 0 to 30. DIP switch settings must agree
When using ChartView with IEEE 488 applications, you must make use of an IOtech Driver 488/W31, /W95,
or /WNT when made available. In addition, the device must be configured in the Driver 488 and be named
WAVE.
NetScan devices can not make use of the IEEE 488 interface.
The RS-232/422 Setup dialog box appears. If "Yes" is chosen for modem, the RS-232/422 Setup window
Setup
changes, allowing you to cancel your call waiting service by entering your cancellation code and your modem
RS-232/422
phone number. The Cancel Code pull-down list provides three common code options. Instead of using a
code from the list, you can type in the desired code. Note that the device DIP switch settings must match
those entered in the text boxes.
Comm Port
Baud Rate
Parity
Handshaking
Modem
Cancel Codes
for Call Waiting
NetScan User's Manual
¾ ¾
with this setup. For ChartScan, an IEEE 488 interface card is required for use of IEEE 488 interface.
NetScan devices can not make use of the IEEE 488 interface.
1-16
300, 600, 1200, 2400, 4800, 9600, 19200
None, Odd, or Even
None or RTS/CTS
No or Yes
*70, 70#, 1170, or type in other acceptable code
ChartView Software Reference
4-23