Omega Engineering OSXL650 User Manual page 12

Low cost professional infrared thermometer
Table of Contents

Advertisement

4-4 Advanced Functions (OSXL653)
4-4-1 AUTO Mode-Continuous
Operation
From the SCAN mode (Trigger is pulled), you can
lock the trigger electronically and measure
temperature continuously (AUTO mode) by pressing
the F key. The AUTO icon will appear on the display.
Pressing the F key again will disable the AUTO
mode. AUTO icon will disappear from the display. If
the trigger is pulled, the unit stays in the SCAN
mode. If the trigger is released, the unit will go to
HOLD mode and will shut itself off after about 6
seconds.
The following table shows an overall functional flow
chart of the thermometer:
Mode
SCAN
AUTO
DATA
DATA Max Temp
Max Temp Max Temp Min Temp
Min Temp Min Temp Avg Temp
Avg Temp
∆T
Emissivity Emissivity High Alarm
HAL
High Alarm Low Alarm + Alarm Set Point – Alarm Set Point
LAL
Low Alarm SCAN/HOLD + Alarm Set Point – Alarm Set Point
8
Press F Key
SCAN AUTO
AUTO DATA
Avg Temp ∆T
T Emissivity
Low Cost Professional Infrared Thermometer
Press Up Key
----
----
+ Memory
Location
----
----
----
----
+ Emissivity
Press Down Key
----
----
- Memory
Location
----
----
----
----
– Emissivity