Korg M1R Owner's Manual page 10

Hide thumbs Also See for M1R:
Table of Contents

Advertisement

NOTE: The
waveforms
of
the
PCM
(Multisound) card are selected
in
the
Oscillator
Assign
function
of
the
EDIT
PROGRAM
Mode
and
the
Drum
Kit
functions
of
the
GLOBAL
Mode.
In
these
exceptions, the
INT
Key and
CARD
Key
are not used.
NOTE: Make
certain
to insert
the card
straight
and
firmly into
the correct
slot.
Cursor Keys and
VALUE
Dial
II
Parameter
values can
be
changed by
pressing
the
cursor
key
below
the
parameter
to
be
edited
on
the display,
then
by
A,
B
C
D
EFGH©
adjusting the
VALUE
dial.
Cursor keys used
to
access
r
I
Y
p^^
"
i
"
~
"
"
f
j
f
r^^"
J
\\
]~
\
j
VJ
different
function
and parameters
will
be
indicated
in
I.
J
squares
(
)
throughout
the
rest
of
this
manual.
UP/DOWN
Keys
These
are
used
when
finely adjusting the
values of parameters
that are difficult
to set
only
by
using
the
VALUE
dial
or
when
making
fine
and
detailed alterations
in
the
sound. Pressing
UP
increases the value
by
1
and
pressing
DOWN
decreases
the
value
by
1.
DOWN
T
i
UP
dZJ
[ZZD
*
Concerning
the
UP/DOWN
keys:
The
cursor
will
appear under
the
Combination/Program
number
at
the
bottom
left
of
the
screen
when
pressing
the
COMBI
key
or
PROG
key
of
the
MODE
SELECT
keys (immediately
after
selecting the
COMBI
or
PROG
Mode).
Pressing
the
UP
key
in this
condition
will
advance
the
Combination
or
Program number by one and
pressing
the
DOWN
key
will
decrease
it
by
one.
*
The
VALUE
dial
cannot be used here
to
change
the
Combination
or
Program.
*
Pressing any of
the
cursor keys
(
[a]
through
[h]
)
will
move
the
cursor
to the
performance
edit
parameters,
and
editing
can be
done by
using
the
UP/DOWN
keys and
the
VALUE
dial.
To
return the
UP/DOWN
keys
to
function
as
Program
up and
down
after
selecting the
performance
edit
mode:
in
PROGRAM
Mode,
press the
PROG
button;
in
COMBINATION
Mode,
press the
COMBI
button.
In
each
case, the
cursor
will
return
to
its
position
under
the
Combination
or
Program number
and
the
UP/DOWN
keys can
be used again
to
increment and decrement
the
Combination
or
Program
number.
PAGE
+/-
Keys
PAGE
PAGE
Each
function of
the
MIR
is
organized
in
display pages.
These keys
allow
you
to
(
I
I
)
access succeeding
and
preceding display pages
by
using
the
PAGE
+
and
PAGE
-
keys, respectively.
START/STOP
Key
INT
CARD
(
1
C
COMBI
eDIT
COMBt
]
I
This
key
is
used
to
start
or
to
stop the sequencer.
If
you
press
this
key
in
any
mode
other than
the
SEQUENCER
Mode,
the
MIR
will
automatically
move
to
the
SEQUENCER
Mode
and
play
will
start.
When
the
sequencer
is
playing,
the
first
beat of
the
measure
is
indicated
on
the
key by
a flashing red
light;
other beats
are
indicated
by
a flashing
green
light.
I
SEQ
1
START/STOP
REC
REG
Key
(
1
COMBt
EDIT
COMBI
This
key
is
used
to
begin recording
when
in
the
SEQ
mode.
The lamp
remains
lit
while
the
sequencer
is
running.
I
SEQ
I
START/STOP
REC
10