  • Page 1: Table Of Contents

    Contents Adapter Plug Model and Serial Numbers Air Direction Problem Solver Appliance Registration Safety Instructions Care and Cleaning User Maintenance Instructions 6 Air Filter Warranty Back Cover Condenser Coils Grilles & Cabinet Consumer Services Control Settings Electrical Requirements Energy-Saving Tips Extension Cords Grounding Installation Instructions...
  • Page 2: Model And Serial Numbers

    See grounding NEXT, if you are still not pleased, Consumer Affairs instructions on page 3. write all the details-including GE Appliances your phone number—to: Appliance Park Never unplug your air conditioner Louisville, KY 40225 Manager, Consumer Relations by ptiling on the power cord.
  • Page 3: Adapter Plug

    Electrical Read Carefully. How to connect 230/208-volt pe~endicular, TEMPORARY METHOD tandem or large tandem type wall electricity ..(ADAPTER PLUGS NOT outlet. These types of outlets are PERMITTED available at most hardware stores. For personal safety, ALIGN LARGE PRONGS/SLOTS this appliance must be properly grounded.
  • Page 4: Thermostat Control

    Operating Your Air Conditioner Controb cOOLER> AIR OUT AIR IN THERMOSTAT SELECTOR Thermostat Control Ventilation Control Selector Switih When the AIR IN and AIR OUT When you turn the Thermostat turns air conditioner off. Control to the desired setting, the buttons are in the out position, the LO FAN provides low fan speed...
  • Page 5: Air Direction

    For normal cooling To adjust air direction For ni@ttime operation Set the Selector Switch at HI Up and down During the cooler evening hours, COOL. we recommend that you set the Selector Switch at LO COOL 2. Set the Thermostat Control at for quieter operation and the the desired number (usually 4-6 is Thermostat Control at mid-range...
  • Page 6: Care And Cleaning

    Grasp the tab at the bottom of the to be steam cleaned, a service avtiable and air inlet grille, pushing the unit and pull downward. through your GE service outlet. Clean the filter with a vacuum cleaner to remove light dust. Wash...
  • Page 7 Moisture removed from indoor air drains to rear of cabinet, where it is picked up by a fan and thrown against the outdoor condenser coil. If you need more help.. call, toll free: GE Answer Center@ 800.626.2000 consumer information service...
  • Page 8: Electrical Requirements

    BEFORE YOU BEGIN Read these instructions completely and INSTALLER—Be sure to leave these instructions with the Consumer. IMPORTANT—Observe all governing CONSUMER—Keep these instructions for codes and ordinances. future reference. ELECTRICAL REQUIREMENTS WINDOW REQUIREMENTS FOR PERSONAL SAFETY: Standard double-hung window with actual opening width of 331/4”...
  • Page 9 REMOVE GRILLE Remove chassis shipping screw located on rear 1. Remove grille insert. of unit. Reinstall screw into base pan to prevent condensate leakage through screw hole. Remove screw securing grille frame to chassis. 2. Unlock chassis security lock located in lower right side above the control box.
  • Page 10 FILLER PANELS. 5. Fit lower halves of U-shaped sliders into bottom WINDOW track. Pivot assembly forward toward sash. 1. Measure center of window opening. Mark center position on both the window sill and the window sash. ‘Sash Raise the window sash. ‘Upper guide 3.
  • Page 11 iNSTALLCA61NET 5. Cut the foam sash-gap gasket to the correct WINDOW. window width and “stuff” it between the top of 1. Remove paper backing from seal strip and the lower sash and the glass pane of the upper affix seal strip to bottom of top channel. sash to provide a seal.
  • Page 12 3. Cabinet is designed with right-side power cord SPECIAl INSTALLATIONS. exit. Power cord is located in cord storage To overcome storm windcw interference, attach compartment in lower right corner of chassis. a 2“ wide wood strip to the stool with either nails Cord pulls out and pushes back easily.
  • Page 13 THE CABINET MAY BE INSTALIEDTHROUGH THE WALL IN pREpAREwALLOPENING. Measure Determine size of opening. width and height of cabinet and add 1/8” to each dimension. side louvers must project on the outdoor side of the wall. The room side of the mbinet must project into the room at least 1“...
  • Page 14 lNSTALLCABINETIN WALL (continued) 3. Secure abinet sides to wooden frame with six 1“ long #10 wood screws and secure cabinet top to Trim frame with four 1“ long #10 wood screws. Molding (if desired) Holes for INSIDE Drill holes in cabinet sides and top, if necessary for proper installation.
  • Page 15: User Maintenance Instructions

    With the purchase of your new appliance, receive the assurance that if’ you ever need information or assis~nce from GE, we’ll be there. N1 you have to do is cdl—toll-free! Whatever your question about any G major appliance, GE Answer Cented information service is available to help.
  • Page 16: Warranty

    To know what your legal rights are in your state, consult your local or state consumer affairs office or your state’s Attorney General. Warrantor: General Electric Company If further help is needed concerning this warranty, write: Manager—Consumer Affairs, GE Appliances, Louisville, KY 40225 Pub. Printed in Brazil...