Technische Daten

System
Spannungsversorgung:
Betriebsspannung ................................................................... 230V~
Netzfrequenz ............................................................................. 50Hz
Max. Leistungsaufnahme ........................................................... 32W
Leistungsaufnahme in Stand-by ................................................ ≤5W
Verstärkerteil
Ausgangsleistung:
Sinusleistung .......................................................................... 2 x 5W
Musikleistung ...................................................................... 2 x 7,5W
Empfangsteil
Empfangsbereich:
FM .......................................................................... 87,5 ...108,0MHz
MW ........................................................................... 522 ... 1620kHz
CD Teil
Frequenzgang .......................................................... 100Hz ... 16kHz
Geräuschspannungsabstand (wtd.) ........................................ ≥60dB
Abmessungen und Gewicht
Abmessungen Gerät B x H x T .......................... 195 x 115 x 242mm
Gewicht Gerät ........................................................................... 2,4kg
Abmessungen Lautsprecher B x H x T .............. 110 x 200 x 207mm
Gewicht pro Lautsprecher ....................................................... 0,75kg

Servicehinweise

Achtung: ESD-Vorschriften beachten
Vor Öffnen des Gehäuses Netzstecker ziehen.
Leitungsverlegung
Bevor Sie die Leitungen und insbesondere die Masseleitungen lösen,
muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet
werden.
Nach erfolgter Reparatur ist es notwendig, die Leitungsführung wieder
in den werkseitigen Zustand zu versetzen um evtl. spätere Ausfälle
oder Störungen zu vermeiden.
CD-Laufwerk
Bei Ausbau der Lasereinheit oder der Servo-Leiterplatte muß vor
Abziehen der Steckverbindung eine Schutzlötstelle auf der Leiter-
platte der Lasereinheit angebracht werden, um eine Zerstörung der
Laserdioden durch statische Aufladung zu vermeiden.
Beim Einbau einer neuen Lasereinheit (CD-Laufwerk) muß nach
Einstecken der Steckverbinder die werkseitig angebrachte
Schutzlötstelle entfernt werden!
Technical Data
System
Power supply:
Operating voltage .................................................................... 230V~
Mains frequency ........................................................................ 50Hz
Max. power consumption ........................................................... 32W
Power consumption in standby .................................................. ≤5W
Amplifier unit
Output:
Sine wave power .................................................................... 2 x 5W
Music signal power ............................................................. 2 x 7.5W
Receiver unit
Reception range:
FM .......................................................................... 87.5 ...108.0MHz
MW ........................................................................... 522 ... 1620kHz
CD unit
Frequency response ................................................ 100Hz ... 16kHz
Noise-voltage ratio (wtd.) ........................................................ ≥60dB
Dimensions and weight
Device dimensions W x H x D ............................ 195 x 115 x 242mm
Device weight ............................................................................ 2.4kg
Loudspeaker dimensions W x H x L .................. 110 x 200 x 207mm
Weight per loudspeaker .......................................................... 0.75kg
Service Hints
Attention: Observe the ESD safety regulations
Disconnect the mains plug before opening the set.
Wiring
Before disconnecting any leads and especially the earth connecting
leads observe the way they are routed to the individual assemblies.
On completion of the repairs the leads must be laid out as originally
fitted at the factory to avoid later failures or disturbances.
CD Mechanism
When removing the Laser pick-up or the Servo PCB, the Laser pick-
up PCB must be provided with a protective soldered joint before
unplugging the connectors to avoid damage to the Laser diodes by
static charges.
When inserting the new Laser pick-up (CD drive mechanism) the
soldered joint fitted at the factory must be removed after the
connectors are plugged in.
Schutzlötstelle
Protective soldered joint
1 - 3