SIMPAL-T2 GSM Temperature Alerter USER MANUAL
StartTime and EndTime: Be consists of 4 digits (hh:mm) and works
on a 24 hour clock. The StartTime and EndTime should be in the
same day, and the EndTime must be later than StartTime. Default
settings: 0700 to 2100.
MinTemp and MaxTemp: The values are whole numbers, can be set
within the range of -10 to 50 centigrade degree. The difference of
MinTemp and MaxTemp values should not be 0.
MinTemp1 and MaxTemp1 are temperature limits within the
duration. Default MinTemp1 is 18 and MaxTemp1 is 24 centigrade
degree.
MinTemp2 and MaxTemp2 are temperature limits beyond the
duration. Default MinTemp2 is 16 and MaxTemp2 is 24 centigrade
degree.
For example: #07#0#0000#2130#18#24#16#24# , 0000 means time
00:00(hh:mm)AM, 2130 means time 9:30PM.
• Successful SMS reply
Schedule temperature alert: ON/ OFF
Everyday
Setting time: ****-****
Temp alert range: **-** degree
Other times temp alert range: **-** degree
The alerter will send SMS message when it alarms:
BUILT-IN TEMPERATURE ALERT.
Current temperature reading: **
2.7.3 Disable timing alarm of built-in sensor
Method
The Master user sends following SMS message in order to:
Disable timing alarm of built-in sensor (Default):
9
Saturday to Sunday
#06#0#
(23)