Indicator lights if keypad installed with PMI panels
The front cover of the keypad features LED indicators which
show the status of your security system.
LED 1 indicator "system status"
On: Total set is being armed.
Flashing: Partial or Annex set is being armed.
Off: The system is disarmed.
LED 2 indicator "memorized alarm"
On: An intrusion occurred during the total set activation of the
system. The indicator remains on until the next activation.
Flashing: An intrusion occurred during the partial or annex
activation of the system. The indicator remains on until the next
activation.
Off: No memorized alarm.
LED 3 indicator "perimetric fault"
Flashing: A window or a door protected by a magnetic contact
is open. It flashes until the window or door has been closed.
Off: No perimetric fault.
LED 4 indicator "system fault"
On: Activation of a technical or smoke detector.
Flashing: This indicates a fault in the system (battery,
supervision or peripheral tamper fault, phone line failure or radio
jamming). The indicator remains on or flashing until the fault is
rectified.
Off: No system fault.