Installation and connection

Electrical connection

The electrical components of this dryer comply with
IEC 335-1 and IEC 335-2-11.
All electrical work must be carried out by a suitably
qualified and competent person in strict accordance
with current local and national safety regulations.
For technical data see data plate or wiring diagram
supplied. The wiring diagram is supplied with the
dryer.
The dryer shall only be operated with the voltage,
frequency and fusing shown on the data plate.
Connection should be made via a suitable isolator in
accordance with national regulations, with an on-off
switch which is easily accessible for servicing and
maintenance work after the dryer has been installed.
An electrical safety test should easily be performed
after installation and after any servicing work.
When hard-wired a main power switch with all-pole
disconnection is to be installed. When switched off
there must be an all-pole contact gap of at least 3
mm in the mains connection switch, which should be
lockable in the neutral position.
The mains connection cable may only be replaced by
an original Miele spare part or an appropriate cable
with wire end ferrules.
If the appliance is disconnected from the electricity
supply ensure adequate measures are taken to
ensure that the appliance cannot be reconnected to
the electricity supply until all work has been carried
out (lockable disconnector or monitoring of
connection site).
After the dryer has been connected to the electricity
supply check the rotation direction of the fan. It
should rotate clockwise. If it rotates counterclockwise,
2 phases on the incoming power supply need to be
exchanged.
Equipotential bonding
Equipotential bonding must be carried out if leak
current > 10mA.
18

Air inlet and exhaust connection

This dryer must only be used when it is connected to
a suitable ducting system. The installation site must
be adequately ventilated. See the installation
instructions supplied.
,
Repairs must only be carried out by a Miele
Service technician. In the event of a fault please
contact the Miele Service Department.
,
After setting up and connecting the appliance,
ensure that all outer casing parts are correctly
fitted back into position.