RM-132; RM-133
Service Tools and Service Concepts
New service tools
The table below gives a short overview of service tools that can be used for testing, error analysis and repair
of product RM-132; RM-133, refer to various concepts.
Issue 1
FS-19
Flash adapter FS-19 is used for phone testing and flashing.
FS-19 is used with the generic flash adapter base SS-60/62 and control
Unit CU-4 or interface adapter SS-46. When flashing or system testing
the phone, the adapter is attached to replace the phone's own battery.
All functions (as well as the calibration voltages, current and the
protections for over voltages, over current and voltage polarity), are
performed by CU-4.
Flash adapter FS-19 main features:
• VBATT supply interface
• USB / FBUS multiplexed interface to the phone
• Supply voltage for light source
MJ-87
The MJ-87 module jig is used for testing the following modules:
• User interface
• Baseband and RF on system module
Note:
The nominal supply voltage for MJ-87 is +6.0 V. The
supply voltage must not exceed +12.0 V (min. 5.0 V).
Supply the power to the jig only when the jumper is open =
regulated.
RF attenuations:
•
Band
GSM850
GSM900
GSM1800
GSM1900
WCDMA2100
COMPANY CONFIDENTIAL
Copyright © 2006 Nokia. All rights reserved.
Flash adapter
Module jig
Table 12 Attenuation values
Attenuation
0.15 dB ± 0.05
0.17 dB ± 0.05
0.36 dB ± 0.1
0.46 dB ± 0.1
0.71 dB ± 0.2
Nokia Customer Care
Page 4 –5