Chapter 2 Mark Pro 2I Assembly; Introduction; Cables, Connectors - Kurzweil Mark Pro 2i Service Manual

Table of Contents

Advertisement

Mark Pro TWOi
Chapter 2
Mark Pro 2i Assembly

Introduction

This chapter contains all the procedures for the disassembly and reassembly of Mark Pro 2i as
well as instruments with factory-installed. There are three main sections: Opening the Mark Pro
2i, Top Enclosure, Mark Pro 2 Keyboard Assembly .
Warning: If possible, save all user programs and setups before disassembly. For instructions.
Notes, Cautions, Warnings
Please pay special attention to all Notes, Cautions, and Warnings as they not only point out
specific instructions .

Cables, Connectors

Flat Ribbon Cables
All flat ribbon cables with connectors are keyed, and therefore cannot be reversed. Most flat
ribbon cables have locking cable clips. Be sure to reapply the clips when connecting cables.
When disconnecting and connecting these cables, you must look for the marking on the edge of
the cable denoting Pin 1 and be sure that you match it correctly with Pin 1 on the board.
Cable Routing
In some cases, tape secures cable connections or fastens cables to the Top enclosure. Always
peel back the tape from one side when disconnecting cables so that the tape remains properly
positioned.
Required Tools and Materials
- screwdriver
10