Disk arrays are made up of physical drives. Logical drives are created on the disk array. When a disk
array and its logical drives go Offline, the data stored in the logical drives is no longer accessible.
RAID 0 logical drives go Offline when ONE physical drive is removed or fails. RAID 1, 1E, 5, and 10
logical drives go Offline when TWO physical drives are removed or fail.
RAID 6 logical drives go Offline when THREE physical drives are removed or fail.
The PROMISE Utility reports these conditions in the following places:
• Dashboard icon – A red X
drives under System Status.
• Physical Drive icon – Physical drives are shown Dead, Offline, or Missing.
• Logical Drive icon – Disk Array and Logical Drives are marked with a red X
• Event icon – Major event for the logical drive and a Warning event for the physical drive. Under
Background Activities, no Rebuild takes place. See Repairing, below.
r
o
ePAiring An
ffline
RAID 1, 1E, 5, 6, and 10 Logical Drives
If a fault-tolerant logical drive, RAID 1, 1E, 5, 6, and 10, goes Offline, it may be possible to recover your
data.
WARNING
WARNING
RAID 0 Logical Drives
If a logical drive based on a non-fault-tolerant disk array, RAID 0, goes offline, all of the data on the
logical drive is lost.
/ l
d
o
ogiCAl
rive
icon appears beside the disk arrays, logical drives, and physical
D
A
l
iSK
rrAy or
ogicAl
ffline
D
rive
130
icon.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pegasus2 r4Pegasus2 r8

Table of Contents