9.
Slightly lift the drip tray up and pull it out of the
appliance. Remove the container from the tray,
empty it and rinse it. Clean the tray and the grid
from water and coffee residues. Reassemble all
the components and put the drip tray back in
place, together with the container (PICTURE F).
10. Push one of the coffee supply buttons to eliminate
the warning of "full used-capsules-container".
The unit enters standby mode after 10 minutes of
inactivity. To turn it on, press the one of the two coffee
supply buttons.
TIPS
Use thick, preheated cups when preparing Espresso:
this will keep your coffee warm for longer.

FREQUENT MAINTENANCE

Daily, wash the supplying unit pressing the long
coffee button without inserting any capsule and
supply water for 10 seconds, then press the
button again to stop. Place a cup to collect the
water dispensed.
Use a wet cloth to clean the unit, do not use
abrasive detergents.
After using the appliance, slightly lift the drip tray
up slightly and pull it out of the appliance. Wash
the components with lukewarm water and a
normal washing-up liquid. Empty the water from
the tank, rinse it and dry it.
DESCALING
Lime scale built-up is a natural consequence of
appliance use. Descaling must be performed once
every 4 weeks; if the water is very hard, descaling
is needed more often. Descaling frequency may be
reduced with soft waters. To descale your appliance,
use any commercially available non-toxic descaling
product.
1.
Unplug the appliance from main supply, remove
the tank and empty it.
2.
Fill the tank with the descaling solution and
follow the instructions on the product package.
3.
Plug the appliance and wait until it heats up.
Press the long coffee button without inserting
any capsule and supply water for 10 seconds,
then press the button again to stop. Place a cup
to collect the water dispensed.
4.
Unplug the appliance from main supply
leave the descaling solution in for about 10-15
minutes, with the appliance off.
18
18
5.
Repeat the procedure of point 3 and 4 until there
is no more descaling solution in the tank.
6.
Remove the water tank, rinse it thoroughly and
fill it again with fresh drinkable water.
7.
Plug the appliance and wait until it heats up.
Press the long coffee button without inserting
any capsule and supply water for 10 seconds,
then press the button again to stop. Repeat the
procedure until the tank is emptied. Place a cup
to collect the water dispensed.
8.
When the tank is empty, Unplug the appliance
from main supply and fill the water tank again
and repeat the procedure from point 6.
9.
When the second rinsing cycle is complete, fill
up the tank again. The appliance will now be
ready for use.
LONG PERIODS WITHOUT USING THE
APPLIANCE
If the appliance is not used for longer periods of
time, switch it off and unplug it from the wall.
Store the appliance in a dry place, away from
dust and out of the reach of children.
It is recommended to store the appliance in its
original packaging.
Temperatures in the storage area should not be
lower than 5° C, in order to avoid any damage
to the inner parts of the appliance due to water
freezing.

SAFEGUARDING THE ENVIRONMENT

DISPOSAL OF PACKAGING MATERIALS
The packaging material is 100%
recyclable and is marked with the recycle
symbol (*). The various parts of the
packaging must therefore be disposed of
responsibility and in full compliance with
local authority regulations governing waste disposal.