Operating instructions SATAjet 1000 K (RP/HVLP), H RP
6.1 Repair instructions for air distribution ring
Important Notes: When pulling off the air distribution ring make sure that the sealing
edges inside the gun body are not damaged. Therefore please proceed with utmost care
when removing the air distribution ring !
1. First of all, remove the nozzle set:
a. Remove air cap
b. Unscrew the material flow control
c. Pull out spring and paint needle
d. Remove paint nozzle (by using the wrench from the tool kit)
2. Removal the air distribution ring (with special tool)
Pull at the special tool or yank out the air distributionring with the
help of a hexagonal key, and remove all dirt reminders.
Please make sure that no dirt has settled down at the sealing
surfaces and no scratches prevent optimum sealing performance!
3. Inserting the new air distribution ring
3a
The new air distribution ring must be inserted in a way that the
plastic pin marked with a arrow (1) fits smoothly into the drilling
marked (2)!
3b
Then firmly push in the air distribution ring, insert the paint nozzle
and tighten slightly, then remove it again. Make sure that the air
distribution ring fits in tightly against the gun body.
4. Mounting the nozzle set
(Proceed in the opposite sense as described under 1.)
Convince yourself of the flawless gun function by producing a test spray pattern
on a piece of paper before continuing to coat any object !