Advertisement

Equipment Shutoff Valve
Gas Meter
Figure 15 - Checking Gas Joints (Natural Gas Only)
5. Correct all leaks at once.
6. Light appliance (see Operation, Page 15). Check all other
internal joints for leaks.
7. Turn off appliance (see To Turn Off Gas to Appliance, Page
15 for Remote Ready models).
INSTALLING SWITCH
The AUTO/OFF/ON switch for this log set is installed into
the small single log accompanying this log set. This switch
needs to be used only if remote or wall switch is not being
used.
Connect the wires to the valve from the switch assembly as
shown in Figure 16.
INSTALLING OPTIONAL REMOTE ACCESSORIES
Installing Remote Receiver
Remote control accessories are available separately (see
Accessories, Page 23). Read instructions shipped with re-
mote control along with instructions below before attempting
installation.
1. If unit is already installed in fi replace, continue with these
instructions. If unit has not been installed in fi replace, go
to step 6 and continue installation of remote accessory.
Control Valve
Figure 16 - Connecting Wires
10
INSTALLATION
Continued
Control Valve
Location
To OFF
Terminal on
Switch
To AUTO
Terminal
on Switch
SuperiorFireplaces.us.com
WARNING: Turn off appliance and let cool
before handling any part of appliance. Make
sure gas is turned of to unit.
2. Carefully remove logs and set aside.
3. Locate mounting screws on sides of appliance base as-
sembly and remove screws. Set screws aside for reinstal-
lation.
4. Disconnect gas line from appliance base as shown in
Figure 9, Page 7.
WARNING: A qualifi ed service person must
connect and disconnect gas to appliance. Fol-
low all local codes.
5. Remove appliance base from fi replace.
6. If installed, disconnect AUTO/OFF/ON switch wire from
control valve at TPTH and TH locations (see Figure 17).
7. Connect wires from hardware pack (with remote receiver
bracket) to control valve at the TPTH and TH locations as
shown in Figure 17. Connect other ends of these wires
to remote receiver wires.
NOTE: Make sure excess wire does not interfere with
burner or pilot.
8. If appliance was removed from fi replace before installation
of remote accessory, see Installing Appliance Base As-
sembly on Page 7 to reinstall appliance into fi replace. Test
gas connection for leaks (see Checking Gas Connections,
Page 9).
9. If logs were removed from appliance for install remote ac-
cessory, replace logs (see Installing Logs, and Volcanic
Stone, Page 11).
10.Place remote receiver on fi replace fl oor next to control
valve. Make sure the remote receiver and wires are not on
or touching either gas burner on the log set.
Installing Batteries for Remote Receiver and Hand Held
Remote Control
Follow instructions accompanying remote control accesory
to install batteries.
NOTE: Only use alkaline batteries.