Superior MNF24INE Installation And Operation Instructions Manual

Superior MNF24INE Installation And Operation Instructions Manual

Unvented (vent-free) gas log heater

Advertisement

P/N 900462-01 Rev. NC 08/2015
P900462-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built
fi replace or in a listed ventless fi rebox enclosure. It is design-certifi ed for these installations in accordance
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fi replace that includes
instructions stating it has not been tested or should not be used with unvented gas logs.
This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on page 6 of this manual.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
Installation and Operation Instructions
Superior
Models
PFS
®
MNF24INE
US
Report No. 10-87
For use with log sets
LMF24GTA, LMF24GTB, LMF30GTA, LMF30GTB, LMF36GTA, and LMF36GTB
®
Unvented (Vent-Free) Gas Log Heater
MNF24IPE
MNF30INE
MNF30IPE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MNF24INE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior MNF24INE

  • Page 1 Installation and Operation Instructions Superior ® Unvented (Vent-Free) Gas Log Heater P/N 900462-01 Rev. NC 08/2015 Models ® MNF24INE MNF24IPE MNF30INE MNF30IPE P900462-01 Report No. 10-87 For use with log sets LMF24GTA, LMF24GTB, LMF30GTA, LMF30GTB, LMF36GTA, and LMF36GTB INSTALLER: Leave this manual with the appliance.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..............2 Cleaning and Maintenance ........ 29 Product Identifi cation ........... 5 Specifi cations ............ 30 Local Codes............5 Wiring Diagram ..........31 Unpacking............5 Troubleshooting ..........32 Product Features ..........6 Accessories ............39 Air For Combustion and Ventilation ..... 6 Parts ..............
  • Page 3 SAFETY Continued WARNING: This product con- WARNING: Do not allow fans tains and/or generates chemicals to blow directly into the fi replace. known to the state of California Avoid any drafts that alter burner to cause cancer or birth defects fl...
  • Page 4 SAFETY Continued 1. This appliance is only for use with the type cleaner or similar products, turn heater off. If of gas indicated on the rating plate. This heated, the vapors from these products may appliance is not convertible for use with create a white powder residue within burner other gases.
  • Page 5: Product Identifi Cation

    3. Check heater for any shipping damage. Sellers of unvented propane or natural If the heater is damaged go to Superior- gas-fi red supplemental room heaters shall Fireplaces.us.com or contact your dealer provide to each purchaser a copy of 527 for information.
  • Page 6: Product Features

    PRODUCT FEATURES OPERATION SAFETY DEVICE This heater is clean burning. It requires no This heater has a pilot with an Oxygen Deple- outside venting. There is no heat loss out a tion Sensing (ODS) safety shutoff system. The vent or up a chimney. Heat is generated by ODS/pilot is a required feature for vent-free both realistic fl...
  • Page 7 AIR FOR COMBUSTION AND VENTILATION Continued Vent-free fi replace __________ Btu/Hr Confi ned and Unconfi ned Space Gas water heater* __________ Btu/Hr The National Fuel Gas Code, ANSI Z223.1/ NFPA 54 defi nes a confi ned space as a space Gas furnace __________ Btu/Hr whose volume is less than 50 cubic feet per...
  • Page 8: Installation

    AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation Ventilation Air From Inside Building grills or ducts. You must provide two perma- This fresh air would come from an adjoining nent openings: one within 12"...
  • Page 9 INSTALLATION CHECK GAS TYPE Use the correct type of gas (natural or propane/ Continued LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where WARNING: Before installing you bought heater for proper type heater. in a solid fuel burning fi...
  • Page 10 INSTALLATION Continued Note: When installing your gas logs into Noncombustible Requirements for a manufactured fi rebox, follow fi rebox Material Distance Safe Installation manufacturer’s instructions for minimum clearances to combustible materials. 12" or more Noncombustible mate- B. Clearances from the top of the fi replace rial OK.
  • Page 11 INSTALLATION Continued MANTEL CLEARANCES NOTICE: Surface temperatures In addition to meeting noncombustible mate- of adjacent walls and mantels be- rial clearances, you must also meet required come hot during operation. Walls clearances between fi replace opening and and mantels above the fi rebox mantel shelf.
  • Page 12 INSTALLATION Continued 3. Mark screw locations through holes in INSTALLING HEATER BASE front panel of base (see Figure 11). If ASSEMBLY installing in a brick-bottom fi replace, mark screw locations in mortar joint of bricks. WARNING: You must secure 4. Remove heater base from fi replace. this heater to fi...
  • Page 13 INSTALLATION Continued with the vent pointing down as shown in Figure CONNECTING TO GAS SUPPLY 12, page 14. Pointing the vent down protects it from freezing rain or sleet. WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to CAUTION: Use only new, the pressure regulator.
  • Page 14 INSTALLATION Continued PROPANE/LP From External Regulator WARNING: Never use an open Equipment Shutoff (11" W.C.** to 14" W.C. Valve With 1/8" fl ame to check for a leak. Apply a Pressure) NPT Tap* noncorrosive leak detection fl uid NATURAL From Gas Meter (5"...
  • Page 15 INSTALLATION Continued Propane/LP PRESSURE TESTING HEATER GAS Equipment Shutoff Valve Supply Tank CONNECTIONS 1. Open equipment shutoff valve (see Figure 14). 2. Open main gas valve located on or near gas meter for natural gas or open pro- pane/LP supply tank valve. 3.
  • Page 16 INSTALLATION Continued Touch Pad Wire Harness POWER SUPPLY AND BATTERY INSTALLATION It is helpful to have a fl ashlight so you can see the connections as described below. Lo- cate the battery power supply. It is the black box with the red and black wires. Locate the control module (see Figure 17).
  • Page 17 INSTALLATION Continued 1. Find the right front log (LMF24GTA/B INSTALLING LOGS, EMBERS AND models: D-061 or LMF30GTA/B models: LAVA ROCK D-019 or LMF36GTA/B models: D-027). See Figures 22, 22A, 22B, and 22C for WARNING: Failure to position reference. The log has a rectangular the parts in accordance with these shape on the bottom that fi...
  • Page 18 INSTALLATION Continued Vertical Portion of Burner Tube Figure 22C - Installing Right Front Log, Figure 23B - Installing Back Left Log Side View (D-018) Rear View 2. Find the back left log (LMF24GTA/B models: D-059 or LMF30GTA/B models: models: D-060 or LMF30GTA/B models: D-017 or...
  • Page 19 INSTALLATION Continued Square Grate Log Notch Grate Finger Log Slot Figure 24B - Installing Front Left Log Figure 25B - Installing Charred Log Top Side View 25, 25A, and 25B. The log has a slot in the models: D-063 or LMF30GTA/B models: bottom that fi...
  • Page 20 INSTALLATION Continued The bottom of the log has a rectangular Back Top Log (D-062, stand off that fits in the slots on the D-023 or D029) Right Split Cross- right side of the front right log and the over Log (D-022) middle split log.
  • Page 21 INSTALLATION Continued EMBER PLACEMENT log set. Platinum Bright Embers give a bright WARNING: All previously ap- glow appearing as hot coals. Should embers plied loose material must be re- need replacing, see Accessories, page 39. moved prior to reapplication. • Platinum Bright Ember placement.
  • Page 22: Operation

    OPERATION B. BEFORE LIGHTING smell all around NOTICE: During initial operation the appliance area for gas. Be sure to of new heater, burning logs will smell next to the fl oor because some give off a paper-burning smell. gas is heavier than air and will settle Orange fl...
  • Page 23 OPERATION Continued REMOTE CONTROL OPERATION BASIC CONSTRUCTION • Touch-Screen LCD and three push buttons will allow input from users. • LCD screen will provide system status & input feedback to user. • Backlight will illuminate LCD screen for 5 seconds after any user input – the 1st touch of the LCD screen will only illuminate the backlight (will not respond to associated zone function).
  • Page 24 OPERATION Continued FUNCTIONAL DESCRIPTION MANUAL OFF MODE: Note: All function adjustments will be auto- • Transmits fl ame OFF command. matically accepted 15-seconds after pressing • Pilot Method: Intermittent Pilot Ignition a given touch zone or button. The user may (IPI)/Spark-to-Pilot only (continuous/ press the MODE/SET button to immediately standing pilot not allowed)
  • Page 25 OPERATION Continued to change the SET TEMP (45-90 deg. F, • MODE Zone: THERMO and ON are 7-32 deg. C); the new set temperature displayed will automatically be accepted after 2 • ROOM TEMP Zone: Measured tempera- seconds. The factory default SET TEMP ture is displayed is 68 deg.
  • Page 26 OPERATION Continued 2. Press the UP or DOWN Buttons to adjust the TIME/PROG Zone for 5 seconds. the day of week (press the MODE/SET • Program OFF LCD Displays: Button or wait for 15 seconds for adjust- • MODE Zone: OFF ment to be accepted, then enter hour of •...
  • Page 27 OPERATION Continued the transmitter reads & updates the room Flame-A (or Main) Adjustment temperature (2-minute update interval). • Transmits a fl ame height setting com- mand to the control module to adjust the PAIRING Flame-A height. The remote and receiver are paired at the •...
  • Page 28 OPERATION Continued TOUCH PAD OPERATION Note: The touch pad includes a red LED This touch control has only 3 buttons for con- display light. If the LED remains on, the black plug is connected upside down. Unplug, turn trolling manually the fl ame of the appliance (see Figure 33).
  • Page 29: Inspecting Burners

    INSPECTING BURNERS CLEANING AND MAINTENANCE Thermocouple Ignitor Electrode WARNING: Turn off heater and let cool before cleaning. Pilot Burner CAUTION: You must keep control areas, burners and circulating air passageways of heater clean. Inspect these areas Figure 34 - Pilot (Natural) of heater before each use.
  • Page 30: Specifi Cations

    Do not move injector holders from their original positions. Injector Holder SPECIFICATIONS Burner Tube Primary Air MNF24INE AND MNF30INE Inlet Holes • Rating (Variable): 28,000/38,000 Btu/Hr Figure 37 - Injector Holder On Outlet Burner Tube • Type Gas: Natural • Ignition: Electronic •...
  • Page 31: Wiring Diagram

    WIRING DIAGRAM SuperiorFireplaces.us.com 900462-01 NC...
  • Page 32: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualifi ed service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 33 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Either the remote or touch pad but- 6. LED is blinking 6. This indicates the battery power is tons are pressed to start the burner low. Replace the batteries in the ignition sequence and there is no power supply box.
  • Page 34 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed on the 1. Gas supply turned off or equip- 1. Turn on gas supply or open equip- remote or touch pad, the pilot sparks ment shutoff valve closed ment shutoff valve.
  • Page 35 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS pilot lights but pilot fl ame goes 1. Equipment shutoff valve not fully 1. Fully open equipment shutoff out before burners light. open valve. 2. Missing or weak batteries at 2. Check batteries and replace if power supply box or remote.
  • Page 36 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner system shuts off. Control 1. Faulty control module 1. Replace control module. module sounds 2 cycles of 3 beeps. Burner system shuts off. Control 1. Remote and control module not 1. Follow Pairing instructions on module sounds 2 cycles of 3 beeps.
  • Page 37 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burners do not light after ODS/ 1. Inlet gas pressure is too low 1. Contact local natural or propane/ pilot is lit LP gas company 2. Burner orifi ce(s) clogged 2. Clean burner(s) (see Cleaning and Maintenance, page 30) or replace burner orifi...
  • Page 38 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 39: Accessories

    ACCESSORIES Purchase these heater accessories from LAVA ROCK your local dealer. If they can not supply Part No. GA6060, Cat. No. F0248 these accessories, visit our website at Su- For all models. Order when additional rock periorFireplaces.us.com. You can also write is desired.
  • Page 40: Parts

    PARTS REMOTE CONTROL MODELS MNF24INE, MNF24IPE, MNF30INE, AND MNF30IPE SuperiorFireplaces.us.com 900462-01 NC...
  • Page 41 PARTS REMOTE CONTROL MODELS MNF24INE, MNF24IPE, MNF30INE, AND MNF30IPE This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 43 of this manual. PART NO. DESCRIPTION QTY. 125219-01 Burner MF Dual Yellow Flame •...
  • Page 42 PARTS LOG SET FOR MODELS MNF24INE, MNF24IPE, MNF30INE, AND MNF30IPE This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 43 of this manual. LMF24GTA/B LMF24GTA/B, LMF24GTA/B NO. PART NO.
  • Page 43: Replacement Parts

    REPLACEMENT PARTS Have ready: Note: Use only original replacement parts. This will protect your warranty coverage for • your name parts replaced under warranty. • your address Contact authorized dealers of this product. • model and serial numbers of your heater •...
  • Page 44: Warranty

    Superior™ Brand Gas Log Set Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Superior™ brand Gas Log Set ("Product") to be free from defects in materials and workmanship at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured by IHP are found to be defec- tive in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components.
  • Page 45 KEEP THIS WARRANTY Model (located on product or identifi cation tag) _____________________________ Serial No. (located on product or identifi cation tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verifi cation. SuperiorFireplaces.us.com 900462-01 NC...
  • Page 46 NOTES SuperiorFireplaces.us.com 900462-01 NC...
  • Page 47 NOTES SuperiorFireplaces.us.com 900462-01 NC...
  • Page 48 P900462-01 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. Printed in U.S.A. © 2015 Innovative Hearth Products P/N 900462-01 Rev.

This manual is also suitable for:

Mnf30ineMnf30ipeMnf24ipe