SERVICE (cont.)

Thermal Cut-off

Location:
The thermal cut-off is located on the tank heater,
FIG. 28.
FIG. 28 THERMAL CUT-OFF
Test Procedures:
1.
Disconnect the brewer from the power source.
2.
Disconnect the thermal cut-off from the tank
heater terminal and the wiring harness.
3.
Check for continuity across the thermal cut-off
terminals using an ohmmeter.
If continuity is present, the thermal cut-off is operat-
ing properly. If continuity is not present as described,
replace the thermal cut-off.
Removal and Replacement:
1.
Disconnect the thermal cut-off from the tank
heater terminal and the wiring harness.
2.
Remove thermal cut-off and discard.
3.
Connect new thermal cut-off to the tank heater
terminal and the wiring harness.
P1698
Page 25
Part II
32440 070700