ReSound ENYA User Manual
Hide thumbs Also See for ENYA:

Advertisement

BEHIND-THE-EAR HEARING INSTRUMENTS
USER GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for ReSound ENYA

  • Page 1 BEHIND-THE-EAR HEARING INSTRUMENTS USER GUIDE...
  • Page 2: Statement

    1999/5/EC (R&TTE). operation. • The declaration of conformity may be consulted at www.resound.com • In US: FCC CFR 47 Part 15, subpart C. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pur- •...
  • Page 3: Important Notice For Prospective Sound Generator Users

    Prescription use of a Tinnitus Sound Generator (TSG) hearing instru- The purpose of medical evaluation is to assure that all medically treatable conditions that may affect tinnitus ment are identified and treated before the sound generator instrument is used. The TSG module should be used as prescribed by your doctor, audiologist or hearing healthcare profes- The sound generator instrument is a tool to generate sounds to be used with appropriate counselling and/ sional.
  • Page 4: Introduction

    Practice and a positive attitude are important in learning to use hearing instruments. Your ReSound instruments have been adjusted according to your individual hearing loss and needs. Some people adjust quickly to wearing hearing instruments in their ears and hearing new sounds;...
  • Page 5: Table Of Contents

    Statement ......2 Using ReSound Hearing Instruments with Using ReSound hearing instruments with Warning to hearing aid dispensers Intended use .
  • Page 6 Front microphone inlet LS977-DW, LS777-DW, LS577-DW EY477-DW, EY377-DW, EY277-DW Back microphone inlet ReSound ENZ0 EY488-DW, EY388-DW, EY288-DW Volume control (optional) Behind-the-Ear (BTE) hearing instruments Left/Right indicator (Left=Blue/Right=Red) type LO85 with FCC ID X26LO85, IC number...
  • Page 7 Traditional fitting ReSound LiNX Battery compartment & On/Off switch (earmould and tube) Sound outlet Front microphone inlet Back microphone inlet ReSound Enya Volume control Direct audio input Left/Right indicator (Left=Blue/Right=Red) Battery lock (optional) 10. Model (in battery chamber) 11. Manufacturer 12.
  • Page 8: Getting Started

    3. Remove the sticker from the battery and let it air for 2 minutes before you insert it. 4. If the hearing instrument is experiencing frequent loss of connection to ReSound Unite accessories, contact your hearing care professional for a list of low impedance batteries.
  • Page 9: Low Battery Indicator

    ReSound TV Streamer, TV Streamer 2, Phone Clip, Phone Clip+, Resound Micro Mic and Resound Multi Mic. At some point the battery level will also be too low to support the remote control functionality as well, and you will once again hear the descending tones.
  • Page 10 Removal (custom earmoulds) Removal (domes/custom earmoulds with thin tubes) 1. Hold a portion of your earmould towards the back of the ear. 1. Hold the thin tube with your thumb and forefinger and remove the tube. 2. Pull the earmould outward and simultaneously rotate the earmould forward. 2.
  • Page 11: Operation Of The Hearing Instrument

    Operation of the hearing instrument Programme button Volume control (optional) Depending on your experience level with hearing instruments, in- dividual hearing needs, and the type of listening environments you The volume control will allow the volume of hearing instruments experience, your hearing care professional may activate additional to be increased or decreased.
  • Page 12: Flight Mode

    For ReSound LiNX , ReSound Enya and ReSound ENZO wireless hearing instruments follow the instructions below to enter and leave flight mode: It is possible to disable wireless operation by opening and closing the battery compartment three times within a ten second period (open-close, open-close, open-close).
  • Page 13: Listen To Radio Or Tv

    Listen to radio or TV Using ReSound Smart Hearing Instruments with iPhone , iPad , and ® ® iPod touch ® (ReSound LiNX and ReSound ENZO When listening to the TV or the radio, start out by listening to news commentators since they usually speak clearly, then try other programmes.
  • Page 14 PhoneNow activation and good receiver. hearing on the telephone. 2. Only use magnets supplied by ReSound. If you have two hearing instruments with the synchronization function enabled, the volume of hearing instru- ment on the non-phone ear will be turned down.
  • Page 15: Telecoil (Optional)

    Connecting/Disconnecting direct audio boot Telecoil (optional) or integrated FM A telecoil can be activated by your hearing care professional and accessed through one of the additional Connecting audio boot and integrated FM programmes. A telecoil picks up a telephone’s magnetic signal and converts it to sound. An optional tel- Direct audio Integrated FM ephone programme may help to improve speech understanding on the telephone.
  • Page 16: Important Points For Fm

    FM integrated with battery door (super power devices only) Important points for FM 1. Your hearing aid professional can replace the standard • Do not use two transmitters on the same FM channel. battery door with a DAI audio boot or integrated FM •...
  • Page 17: Battery Door Lock (Optional)

    (see illustration) To unlock the battery door of Resound LiNX² and Resound ENZO² 88: 3. With the battery door in its off position, slide the battery...
  • Page 18: Care And Maintenance

    Advanced battery door lock (for Super Power devices only) Care and maintenance Super Power devices (marked as 90) are equipped with integrated advanced battery Please follow the instructions below to prolong the durability of your hearing instruments: door lock. To operate lock use attached tool. 1.
  • Page 19: Daily Maintenance

    Note: Earmould tubing may become stiff, brittle, or discoloured over time. Con- could result in the dome falling out in the ear. tact your hearing care professional regarding tube changes. ReSound Standard domes Cleaning thin tubes and domes 1. Push the new dome over the ribs on the thin tube.
  • Page 20: Smart Phone Apps

    ReSound Tulip domes • If you would like a printed version of the user guide for a Resound smart app please consult customer support or our website. Tulip domes are mounted in a similar manner to standard domes, but a few extra steps are required. Tulip domes consist of two “petals”.
  • Page 21: General Warnings

    Other types * ReSound wireless devices include a RF transmitter that operates in the range of 2.4 GHz - 2.48 GHz. of radiation, such as burglar alarms, room surveillance systems, radio equipment, mobile telephones, * For use of wireless functionality only use ReSound Unite accessories.
  • Page 22: Tinnitus Sound Generator (Tsg) Module

    Your ReSound hearing instrument includes the Tinnitus Sound Generator function, a tool for generating If you have two wireless hearing aids that support ear-to-ear synchronisation this functionality can be ena- sounds to be used in tinnitus management programmes to relieve suffering from tinnitus.
  • Page 23: Using Tsg With Smart Phone Apps

    Using TSG with smart phone apps Technical Specifications The tinnitus sound generator control via hearing aid push buttons can be enhanced with wireless control Audio signal technology from a TSG control app on a smart phone or mobile device. This functionality is available in supported Digital hearing aids when a hearing healthcare professional has enabled the TSG functionality during fitting of the hearing aid.
  • Page 24: Tsg Warnings

    TSG warnings TSG warning to hearing healthcare professionals • Sound generators can be dangerous if improperly used. A hearing healthcare professional should advise a prospective sound generator user to consult promptly • Sound generators should be used only as advised by your doctor, audiologist, or hearing healthcare with a licensed physician (preferably an ear specialist) before getting a sound generator if the hearing professional.
  • Page 25: Battery Warning Information

    Battery warning information Warning to hearing aid dispensers (US Only) Batteries, although very small, contain dangerous substances, and should be disposed of carefully. This is A hearing aid dispenser should advise a prospective hearing aid user to consult promptly with a licensed for the safety of you and the environment.
  • Page 26: Important Notice For Prospective Hearing Aid Users (Us Only)

    Important notice for prospective hearing aid users (US Only) Children with hearing loss (US Only) Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed In addition to seeing a physician for a medical evaluation, a child with a hearing loss should be directed to physician (preferably a physician who specializes in diseases of the ear) before purchasing a hearing aid.
  • Page 27 POWER BTE Models: LS977-DW, LS777-DW, LS577-DW Models: LS988-DW, LS788-DW, LS588-DW, EN988-DW, MAXIMUM OUTPUT (OSPL 90) MAXIMUM OUTPUT (OSPL 90) EN788-DW, EN588-DW 2cc Coupler 2cc Coupler Metal Open Closed Plastic hook hook (HP) Reference test gain (60 dB SPL input) Reference test gain (60 dB SPL input) Full-on gain (50 dB SPL Input) Full-on gain (50 dB SPL Input) dB SPL...
  • Page 28 Mini BTE SUPER POWER BTE Models: EY467-DW, EY367-DW Models: EN998-DW, EN798-DW, EN598-DW MAXIMUM OUTPUT (OSPL 90) MAXIMUM OUTPUT (OSPL 90) 2cc Coupler 2cc Coupler Open Closed Reference test gain (60 dB SPL input) Reference test gain (60 dB SPL input) Full-on gain (50 dB SPL Input) Full-on gain (50 dB SPL Input) dB SPL...
  • Page 29 POWER BTE Models: EY477-DW, EY377-DW, EY277-DW Models: EY488-DW, EY388-DW, EY288-DW MAXIMUM OUTPUT (OSPL 90) MAXIMUM OUTPUT (OSPL 90) 2cc Coupler 2cc Coupler Metal Open Closed Plastic hook hook (HP) Reference test gain (60 dB SPL input) Reference test gain (60 dB SPL input) Full-on gain (50 dB SPL Input) Full-on gain (50 dB SPL Input) Maximum output (90 dB SPL input)
  • Page 30: Troubleshooting Guide

    Troubleshooting Guide SYMPTOM CAUSE POSSIBLE REMEDY No sound Not turned on Turn on by closing the battery door Dead battery Replace battery Battery door will not close Insert battery properly Blocked earmould or tube Clean earmould or tube Blocked wax filter Replace wax filter or consult your hearing care professional Not loud enough Incorrect earmould placement...
  • Page 31 Troubleshooting Guide SYMPTOM CAUSE POSSIBLE REMEDY Excessive whistling / Incorrect earmould placement Re-insert earmould carefully feedback Incorrect dome placement Re-insert dome Excessive ear wax Consult your hearing care professional Feedback control may need adjustment Consult your hearing care professional Earmould tubing worn or damaged Consult your hearing care professional Thin tube connection loose Change thin tube or consult your hearing care professional...
  • Page 32: Warranty And Repairs

    Warranty and repairs Be aware of information marked with the warning symbol ReSound provides a warranty on hearing instruments in the event of defects in workmanship or materials, WARNING points out a situation that could lead to serious injuries, as described in applicable warranty documentation. In its service policy, ReSound pledges to secure func- CAUTION indicates a situation that could lead to minor and moderate injuries tionality at least equivalent to the original hearing instrument.
  • Page 33 Fax: +44 1869 343 466 www.gnresound.com.au Fax: (free) 0800 007 695 CVR no. 55082715 www.gnresound.co.uk www.gnresound.co.nz Any issues relating to the EU Medical Device Directive 93/42/EEC, or Council Directive 1999/5/EC on Radio Equipment and Telecommunications terminal equipment should be directed to ReSound A/S...